Tabs-only node, Environmental specifications, Technical and regulatory compliance – Verilink NCM 2000 (880-502623-001) Product Manual User Manual

Page 23: Tabs-only node -13

Advertising
background image

NCM Overview

Verilink NCM 2000

1-13

TABS-Only Node

For each shelf that contains only TABS based cards, use the
M

ANAGEMENT

B

US

I

N

and O

UT

connectors on the rear of that shelf to

connect it to any other shelf in the node. Use one of the RJ-11 type
cables listed above. One end of the cable must be connected to an
I

N

RJ-11 while the other end is connected to an O

UT

RJ-11 on the

next shelf. No configuration changes are required in the TABS-
based cards in order for the NCM to manage them.

When introducing an NCM to an existing node, any SCC controller
card (SCC 2020, SCC 2130) must be removed.

Environmental Specifications

Table 1-5 Non-operating Environmental Specs

Table 1-6 Operating Environmental Specs

Technical and Regulatory Compliance

This product complies with the following regulatory specifications as they
apply to telecommunications equipment:

FCC part 68

CSA/DOC

Specification

Value (or range)

Storage Temperature Range

-20 to +80

°°°°

C

Max Rate of Temperature Change

8

°°°°

C per hour

Humidity

0% to 95% relative humidity, non-condensing

Vibration in Transport

0.5G from 5 Hz, 3.0G from50 Hz to 500 Hz

Shock During Shipping

20 msec, 25G half sine shock pulse

80 G peak, half sine for 10 msec

Specification

Value (or range)

Temperature Range

0 to 50×C

Moisture

0% to 95% relative humidity, non-condensing

Airborne Contamination

0 to 75 micrograms per cubic meter

Noise

to 75 dBA

Power Consumption

10 Watts total front and back modules

Heat Dissipation

34 BTUh

Advertising