Verilink Productivity 500 (34-00236) Product Manual User Manual

Page 21

Advertising
background image

Network Setup

500 TA

Page 21

Provider

Switch

Type

Provider

Supplied

Info

500 TA Switch Options

AT&T

Multi-Point

2 SPIDs

2 DNs

1) Set Switch Type to AT&T
2) Set Switch Version to AT&T Multi-Point
3) Set Data TEI to Auto
4) Set Data SPID and DN to provider supplied SPID

and DN

5) Set Voice TEI to Auto
6) Set Voice SPID and DN to provider supplied SPID

and DN

AT&T

Point-to-Point

1 DN

1) Set Switch Type to AT&T
2) Set Switch Version to AT&T
3) Point-to-Point
4) Set Data TEI to Auto
5) Set Data DN to provider supplied DN
6) Set Voice TEI to Disabled

Northern Telecom

DMS100

PVC IC-0

DMS100
PVC IC1

(simultaneous

voice and data)

2 SPIDs

2 DNs

1) Set Switch Type to Northern Telecom DMS100
2) Set Switch Version to PVC IC-0 or PVC IC-1

(depending on information supplied to you)

3) Set Data TEI to Auto
4) Set Data SPID and DN to provider supplied Data

SPID and DN

5) Set Voice TEI to Auto
6) Set Voice SPID and DN to provider supplied Voice

SPID and DN

Northern Telecom

DMS100
PVC IC-0

DMS100
PVC IC1

(voice or data, not
simultaneous)

1 SPID

1 DN

1) Set Switch Type to Northern Telecom DMS100
2) Set Switch Version to PVC IC-0 or PVC IC-1

(depending on information supplied to you)

3) Set Data SPID and DN to provider supplied SPID

and DN

4) Set Voice TEI to Disabled
5) Set Voice SPID and DN to provider supplied SPID

and DN

National ISDN

-----------

Same as Table 1

Advertising