Appendix C

500 TA

Page 95

S26=

RTS to CTS time

Range: 0-255 default (1)
Units = 1/100 seconds

&Cn

Data Carrier Detect

n = 0

Always On <default>

n = 1

Tracks Connection (async only)

n = 2

always except during S10
disconnect (async only)

&Dn

Data Terminal Ready (DTR)

n = 0

Ignore DTR (async / sync)
<default>

n = 1

Recall ACU (async only)

n = 2

Hangup - auto answer disabled
while DTR down (async only)

n = 3

Hangup - reset port

n = 9

DTR Dial

&Ln

Persistent DTR Dialing

n = 0

Disable

n = 1

Enable

&Mn

Sync mode

n = 0

Async <default>

n = 1

Sync - DTR disc delay (S25)

n = 2

Sync - DTR dialing (auto answer
disabled while DTR down)

&Rn

Clear to Send (CTS)

n = 0

CTS follows RTS

n = 1

CTS always on when on-line
<default>

&Sn

Data Set Ready (DSR)

n = 0

DSR always on <default>

n = 1

DSR on after protocol installed
except test modes

&Yn

Select Powerup Stored Profile

n = 0

Select stored Profile 0 upon
powerup or DTR reset <default>

n = 1

Select Stored Profile 1 upon
powerup or DTR reset

&Zn=

Store Telephone Number

n = 0-9
n = 0-40 characters (0-9,#,*)

\Qn

Flow Control

n = 0

Disable flow control

n = 1

Enable bidirectional XON/XOFF
flow control

n = 2

Enable unidirectional CTS flow
control

n = 3

Enable bidirectional RTS/CTS
flow control <default>

n = 4

Enable unidirectional
XON/XOFF flow control

CMD

DESCRIPTION

POSSIBLE VALUES