NOTE: The 500 TA voice port will answer speech or audio calls only. The
voice port answer options are not configurable.

Echo Disable Tone

%A96

This command instructs the 500 TA whether or not to generate an Echo Dis-
able Tone. When selected the 500 TA will send a tone at the beginning of the
data call that will disable the echo canceller.

Dialing Method

%A97

This command instructs the 500 TA as to the type of dialing method used when
placing a data call. In most cases the default of Enbloc is correct; however, in
some instances it may be necessary to change to Overlap dialing for the call to
complete properly.

Data Port Originate Mode

%A98

This command alters the bearer capability (BC) sent to the switch in placing
outgoing data calls. Placing an outgoing data call with voice BC (3.1 kHz
audio) may often facilitate completing a call through the network. The answer-
ing unit must be able to receive a voice BC call as if it were a data BC call.

Voice Port Originate Mode

*%A98

This command has the same effect as the %A98 command for the data port
except that the voice port cannot be configured to originate with data BC.

Command

Operation

%A96=0

Off

(default)

%A96=1

On

Command

Operation

%A97=O

Overlap

%A97=E

Enbloc

(default)

Command

Operation

%A98=D

Originate with data BC

(default)

%A98=A

Originate with 3.1 kHz audio BC

%A98=S

Originate with speech BC