Back space character s5, Escape sequence guard time s12, Dte guard @g – Verilink Productivity 500 (34-00236) Product Manual User Manual
Page 56

Page 56
500 TA
Option Configuration
Back Space Character
S5
This command configures the character sent by the AT command processor
to back up one space in the command line. The standard character used for
this is the ASCII backspace (8).
Escape Sequence Guard Time
S12
This command sets the escape sequence guard time--the minimum pause
before and after the escape characters (pause, +++,pause). The guard time also
defines the maximum amount of time between each of the three characters in
the escape sequence. This becomes significant only at low data rates and small
pauses. The guard time is in 0.02 second increments.
DTE Guard
@G
This command prevents any changes to the options via the PC except for the
duration of the call. It disables AT commands which write to the stored profile
(&W and &Z) and causes the 500 TA to reload all options from stored profile 0
at the end of each call.
Command
Operation
S5=
Range: 0-127
default (8)
Command
Operation
S12=
Range: 0-255
default (50)
Units = 1/50 seconds
Command
Operation
@G=D Disable
DTE
Guard
@G=E
Enable DTE Guard