Upgrading flashbank b, Upgrading flashbank b -21 – Verilink SCC 2020 (880-503268-001) Product Manual User Manual

Page 43

Advertising
background image

Configuration

Verilink SCC 2020 User Manual

3-21

Upgrading

Flashbank B

Use this procedure to upgrade flashbank B only if one of the
following is true:

• Flashbank A contains version 1.69C firmware.

• Flashbank A contains a version of firmware higher than

1.80.

The top line of the SCC 2020 Main Menu indicates which version of
firmware is currently running and the second line indicates which
flashbank the current firmware was loaded from. To determine
which version of firmware is in the other flashbank, use the boot
option on the Node Administration Menu and select that
flashbank..

You will need to

know

The IP address of the FTP server.

The absolute path to the directory containing the Verilink SCC
upgrade files.

The password, if required, for accessing the FTP server.

NOTE: If you received the Verilink SCC files in a PKZIPped format,

first extract them using PKUNZIP. Two files may be found,

FLASH.A and FLASH.B. For this procedure only FLASH.B is

required.

Step by Step

1. Using either direct connection to the Craft port, or Telnet,

open a Craft session to the SCC card to be upgraded.

2. Use the “O” command to select the Node Administration

Menu.

3. Type “B” to reboot.

NOTE: The boot command reboots only the SNMP and Craft

interface functions of the SCC 2020, any user data passing

through the CSU portion of the SCC 2020 will not be affected.

4. Select flashbank A.

5. When the

pSH+>

pSH+>

pSH+>

pSH+> prompt returns type “FTP <IP address of FTP

server>”.

6. Login to the FTP server using the method required by your FTP

server program.

7. Use the “CD” command to change to the directory where you

previously placed the file FLASH.B.

8. Use “DIR” or “ls -l”, as appropriate, to produce a long display of

the files in this directory.