Test procedures, Verifying a t1, Test procedures -8 – Verilink SCC 2020 (880-503268-001) Product Manual User Manual

Page 66: Verifying a t1 -8

Advertising
background image

Diagnostics

5-8

Verilink SCC 2020 User Manual

Test Procedures

Testing may generally be divided into two categories, tests which
are conducted to verify an installation where no known problems
exist; and tests which result from an effort to troubleshoot a
problem which is known to exist.

Two procedures are described below. First, in the section

Verifying

A T1

, a method is described to test a T1 circuit when it is expected

that no trouble will be found. Then, in the section

Troubleshooting

,

a suggested method for finding T1 problems is detailed.

Verifying A T1

For this procedure a pattern will be sent from a local CSU, through
the entire transmit path of the T1 circuit, to a loopback in a far end
CSU, then back through the other direction of the T1 circuit.

First a loop-up code is sent, then a test pattern is transmitted.

The data received from the T1 circuit will be compared to the data
which was transmitted. If the data received is identical to the data
which was transmitted, the T1 is good and may be placed into
service.

Far End Loop

To begin the verification, use the Inband Up command on the
Diagnostics Menu. This causes the local CSU to transmit a loop-up
code in the direction of the far end CSU

Figure 5-3

Sending Loop-up Code.

If the loop-up code reaches the far CSU and it is optioned to
respond to loop-up codes, then the far CSU enters a line loop
condition. Now the local CSU receives whatever it is sending.

NOTE: Whenever the Inband Up command is used to send a loop-up

code to a far end CSU, the Inband Down command must be

used later to send the loop-down code. Otherwise the far end

CSU will be left in a looped condition.

Sending A Pattern

Begin transmitting a test pattern by using the qrss command.

Verify that the pattern received matches the pattern being
transmitted by using the show cntr command.

Loop-up code

Far CSU

Local SCC 2020