Configuration

3-26

Verilink SCC 2020 User Manual

41

SCC 2020

TAC 2010

Canned configuration #2, EQPT=ESF/AMI NET=ESF/AMI

42

SCC 2020

TAC 2010

Canned configuration #3, EQPT=SF/AMI NET=ESF/B8ZS

43

SCC 2020

TAC 2010

Canned configuration #4, EQPT=SF/B8ZS NET=ESF/B8ZS

44

SCC 2020

TAC 2010

Canned configuration #5, EQPT=ESF/B8ZS NET=ESF/B8ZS

45

Not applicable (The SCC does not support storing and restoring

module configurations as the older NCC node controller modules did)

46

Not applicable (The SCC does not support storing and restoring

module configurations as the older NCC node controller modules did)

47

SCC 2020

TAC 2010

TAC 2130

Network LBO = 0 dB; Typical value, use when a T1 installed by a local

Bell carrier is terminated in a “smart jack”, (network termination

device) or the first repeater is 2000 to 3000 feet away

48

SCC 2020

TAC 2010

TAC 2130

Network LBO = 7.5 dB; Attenuates transmit signal by 7.5db, USE ONLY

IF NO SMART JACK IS PRESENT , implies that the first active device

(repeater, T3 mux, far CSU) is 1000 to 2000 feet away

49

SCC 2020

TAC 2010

TAC 2130

Network LBO = 15 dB; Attenuates transmit signal by 15db, USE ONLY

IF NO SMART JACK IS PRESENT , implies that the first active device

(repeater, T3 mux, far CSU) is 0 to 1000 feet away

50

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 0-132 ft

51

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 133-265 ft

52

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 266-398 ft

53

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 399-532 ft

54

SCC 2020

TAC 2010

Selects DSX-1 Equipment cable length of 533-655 ft

55

SCC 2020

TAC 2010

Set data bus to NONE (CSU mode) [default]

56

SCC 2020

TAC 2010

DIU 2140

Set data bus to A (Mux mode)

57

SCC 2020

TAC 2010

DIU 2140

Set data bus to B (Mux mode)

Code

Applies to

Description