Thumbwheel procedure, Thumbwheel commands, Thumbwheel procedure -25 thumbwheel commands -25 – Verilink SCC 2020 (880-503268-001) Product Manual User Manual

Page 47

Advertising
background image

Configuration

Verilink SCC 2020 User Manual

3-25

Thumbwheel

Procedure

A four-step procedure is used for each thumbwheel command:

1. Set the thumbwheel to the number, 01 through 30, equal to the

slot number of the module to be optioned. If a node consists
of Multi-line shelves, the first slot in shelf two would be
numbered as 14 and the last slot 26. In a node consisting of all
Dual-line shelves, the first (left-hand) slot of a second shelf is
number 03.

2. Rapidly press the EXE pushbutton twice, as if double-clicking a

mouse. If the SCC 2020 accepts your double-click, the STAT
LED on the selected module will begin to blink green to off. If
the STAT LED does not begin to blink try double clicking again
at a slightly faster or slower rate. Do not proceed to step 3
until the STAT LED on the desired module begins to blink.
Once the STAT LED does begin to blink, steps 3 and 4 must be
completed within 60 seconds or the thumbwheel command
procedure will time-out.

3. Set the thumbwheel switches to the command value which is

to be used, per

Table 3-8

below.

4. Double-click the EXE pushbutton again. If the SCC 2020

module accepts your double-click, the STAT LED on the
selected module will stop blinking green to off and return to
some other state. If the STAT LED on the module continues to
blink green to off, the SCC 2020 did not accept your double-
click. Try double-clicking again, at a faster or slower rate. If
you are not successful within 60 seconds of the time you
selected the module in step 2, the module will timeout and
return to its normal state. If this happens, start over with step
1 of this procedure.

Thumbwheel

Commands

The chart in

Table 3-8

lists the commands available through the

front panel thumbwheels.

Table 3-8

Thumbwheel Switch Commands

Code

Applies to

Description

01 to 30

Any of first

30

modules

Selects a module in the indicated slot, up to slot 30. Thumbwheel

switches cannot be used for modules in slots 31-52

31

SCC 2020

Accesses the controller functionality of the SCC 2020 node controller

(not the T1 CSU portion). For an SCC 2020 in slot 1 of shelf 1, use

address 01 to set CSU options

32

SCC 2020

Reset modem interface by sending the configured modem

initialization string to the DB-9 SLIP port

40 SCC

2020

TAC 2010

Canned configuration #1, EQPT=SF/AMI NET=ESF/AMI

Advertising