Datum setting without a 3-D touch probe 15.6

15

TNC 640 | User's ManualDIN/ISO Programming | 1/2015

507

15.6

Datum setting without a 3-D touch
probe

Note

Setting the datum with a 3-D touch probe: see

"Datum setting with 3-D touch probe ", page 527.

You fix a datum by setting the TNC position display to the

coordinates of a known position on the workpiece.

Preparation

Clamp and align the workpiece
Insert the zero tool with known radius into the spindle
Ensure that the TNC is showing the actual position values

Setting datum with an end mill

Protective measure

If the workpiece surface must not be scratched, you

can lay a metal shim of known thickness d on it.

Then enter a tool axis datum value that is larger than

the desired datum by the value d.

Select the

Manual Operation mode

Move the tool slowly until it touches (scratches)

the workpiece surface

Z

Select the axis

DATUM SETTING Z=

Zero tool in spindle axis: Set the display to a

known workpiece position (e.g. 0) or enter the

thickness d of the shim. In the tool axis, offset the

tool radius

Repeat the process for the remaining axes.
If you are using a preset tool, set the display of the tool axis to the

length L of the tool or enter the sum Z=L+d

The TNC automatically saves the datum set with the

axis keys in line 0 of the preset table.