background image

Thermal Relay

Trip Contact

Drive

CDBR dynamic

braking unit

Thermal Overload

Protector Trip Contact

1

2

P

3

4

3

+

+ 0

− 0

B

+

Dynamic braking

resistor

Figure 19 Connecting a CDBR Dynamic Braking Unit and Dynamic Braking Resistor on Models 4T0088o to 4T0675o

Note:

To install a CDBR dynamic braking unit to models 4T0058o and 4T0072o with built-in dynamic braking transistors, first connect terminal

B1 to the positive terminal on the CDBR dynamic braking unit, then wire the negative terminals on the drive and braking unit together.

Terminal B2 is not used.