PARA- ADDR CLASS 100

NAME

DATA

SETTING RANGE

SETTING

FACTORY

METER

INST. 01

(AND UNITS)

INCREMENT SETTING

n018

112h

12h

Accel/Decel Time

0

0:

0.1

1 (sec)

0

Setting Unit

1

1:

0.01

n019

113h

13h

Acceleration Time 1 (Note 4)

0.00 to 600.0

0.01 (sec)

n020

114h

14h Deceleration Time 1 (Note 4)

-

or

or

n021

115h

15h

Acceleration Time 2 (Note 4)

0.0 to 6000

0.1 (sec)

10.0

n022

116h

16h

Deceleration Time 2 (Note 4)

(Dependent on n018 setting)

0

0:

No S-curve

n023

117h

17h

S-curve Selection

1

1:

0.2 second

1

0

2

2:

0.5 second

3

3:

1.0 second

n024

118h

18h

Freq. Reference 1 (Note 4)

6.00

n025

119h

19h

Freq. Reference 2 (Note 4)

0.00

n026 11Ah

1Ah

Freq. Reference 3 (Note 4)

0.01 (Hz)

0.00

n027 11Bh

1Bh

Freq. Reference 4 (Note 4)

-

0.00 to 400.00

(< 100 Hz)

0.00

n028 11Ch

1Ch

Freq. Reference 5 (Note 4)

or

0.00

n029 11Dh

1Dh

Freq. Reference 6 (Note 4)

0.1 (Hz)

0.00

n030 11Eh

1Eh

Freq. Reference 7 (Note 4)

(>= 100 Hz)

0.00

n031 11Fh

1Fh

Freq. Reference 8 (Note 4)

0.00

n032 120h

20h

Jog Freq. Reference (Note 4)

6.00

n033 121h

21h

Frequency Reference Upper

-

0. to 110

1(%)

100

Limit

n034 122h

22h

Frequency Reference Lower

-

0. to 110

1(%)

0

Limit

0: 0.01 Hz (less than 100 Hz) / 0.1 Hz

Digital Operator

1: 0.1%

n035 123h

23h

Display Mode

2 - 39: rpm

1

0

40 - 3999: custom

0.1 to 49.5 Amps

n036 124h

24h

Motor Rated Current

-

(Up to 150% of Drive rated current)

0.1 (A)

(Note 1)

0

0: Short term rating

n037 125h

25h

Electronic Thermal Overload

1

1: Standard rating

1

0

Protection (for OL1 fault)

2

2: Disabled

n038 126h

26h

Electronic Thermal Overload

-

1 to 60

1 (min)

8

Protection Time Constant

0

0: Operates only when Drive is running

n039 127h

27h

Cooling Fan Operation

(continues operation for 1 minute after

1

0

Selection

Drive is stopped)

1

1: Operates with power applied to Drive

n040 128h

28h

Motor Rotation

0

0: Rotate C.C.W.

1

0

1

1: Rotate C.W. (or opposite direction)

n041 129h

29h

Acceleration Time 3

0.00 to 600.00

0.01 (sec)

(Note 4)

n042 12Ah

2Ah

Deceleration Time 3

or

or

(Note 4)

-

n043 12Bh

2Bh

Acceleration Time 4

0.0 to 6000.0

0.1 (sec)

10.0

(Note 4)

n044 12Ch

2Ch

Deceleration Time 4

(Dependent on n018 setting)

(Note 4)

0

0: Fwd / Rev command (3 wire control)

n050 132h

32h

Multi-function Input

[can only be set in n052]

1

Selection 1 (Terminal S1)

1

1: Forward run (2 wire control)

1

(1)

2

2: Reverse run (2 wire control)

3

3: External Fault (N.O.)

n051 133h

33h

Multi-function Input

4

4: External Fault (N.C.)

2

Selection 2 (Terminal S2)

5

5: Fault Reset

1

(2)

6

6: Multi-step speed ref. cmd. A

n052 134h

34h

Multi-function Input

7

7: Multi-step speed ref. cmd. B

1

3

Selection 3 (Terminal S3)

8

8: Multi-step speed ref. cmd. C

(0)

Drive Parameters - Continued

Section 9

Drive Parameter Listing

(n018-n052)

IG.V7N.qxd:IG.V7N.qxd 6/5/07 3:22 AM Page 27