PARA- ADDR CLASS 100
NAME
DATA
SETTING RANGE
SETTING
FACTORY
METER
INST. 01
(AND UNITS)
INCREMENT SETTING
n018
112h
12h
Accel/Decel Time
0
0:
0.1
1 (sec)
0
Setting Unit
1
1:
0.01
n019
113h
13h
Acceleration Time 1 (Note 4)
0.00 to 600.0
0.01 (sec)
n020
114h
14h Deceleration Time 1 (Note 4)
-
or
or
n021
115h
15h
Acceleration Time 2 (Note 4)
0.0 to 6000
0.1 (sec)
10.0
n022
116h
16h
Deceleration Time 2 (Note 4)
(Dependent on n018 setting)
0
0:
No S-curve
n023
117h
17h
S-curve Selection
1
1:
0.2 second
1
0
2
2:
0.5 second
3
3:
1.0 second
n024
118h
18h
Freq. Reference 1 (Note 4)
6.00
n025
119h
19h
Freq. Reference 2 (Note 4)
0.00
n026 11Ah
1Ah
Freq. Reference 3 (Note 4)
0.01 (Hz)
0.00
n027 11Bh
1Bh
Freq. Reference 4 (Note 4)
-
0.00 to 400.00
(< 100 Hz)
0.00
n028 11Ch
1Ch
Freq. Reference 5 (Note 4)
or
0.00
n029 11Dh
1Dh
Freq. Reference 6 (Note 4)
0.1 (Hz)
0.00
n030 11Eh
1Eh
Freq. Reference 7 (Note 4)
(>= 100 Hz)
0.00
n031 11Fh
1Fh
Freq. Reference 8 (Note 4)
0.00
n032 120h
20h
Jog Freq. Reference (Note 4)
6.00
n033 121h
21h
Frequency Reference Upper
-
0. to 110
1(%)
100
Limit
n034 122h
22h
Frequency Reference Lower
-
0. to 110
1(%)
0
Limit
0: 0.01 Hz (less than 100 Hz) / 0.1 Hz
Digital Operator
1: 0.1%
n035 123h
23h
Display Mode
2 - 39: rpm
1
0
40 - 3999: custom
0.1 to 49.5 Amps
n036 124h
24h
Motor Rated Current
-
(Up to 150% of Drive rated current)
0.1 (A)
(Note 1)
0
0: Short term rating
n037 125h
25h
Electronic Thermal Overload
1
1: Standard rating
1
0
Protection (for OL1 fault)
2
2: Disabled
n038 126h
26h
Electronic Thermal Overload
-
1 to 60
1 (min)
8
Protection Time Constant
0
0: Operates only when Drive is running
n039 127h
27h
Cooling Fan Operation
(continues operation for 1 minute after
1
0
Selection
Drive is stopped)
1
1: Operates with power applied to Drive
n040 128h
28h
Motor Rotation
0
0: Rotate C.C.W.
1
0
1
1: Rotate C.W. (or opposite direction)
n041 129h
29h
Acceleration Time 3
0.00 to 600.00
0.01 (sec)
(Note 4)
n042 12Ah
2Ah
Deceleration Time 3
or
or
(Note 4)
-
n043 12Bh
2Bh
Acceleration Time 4
0.0 to 6000.0
0.1 (sec)
10.0
(Note 4)
n044 12Ch
2Ch
Deceleration Time 4
(Dependent on n018 setting)
(Note 4)
0
0: Fwd / Rev command (3 wire control)
n050 132h
32h
Multi-function Input
[can only be set in n052]
1
Selection 1 (Terminal S1)
1
1: Forward run (2 wire control)
1
(1)
2
2: Reverse run (2 wire control)
3
3: External Fault (N.O.)
n051 133h
33h
Multi-function Input
4
4: External Fault (N.C.)
2
Selection 2 (Terminal S2)
5
5: Fault Reset
1
(2)
6
6: Multi-step speed ref. cmd. A
n052 134h
34h
Multi-function Input
7
7: Multi-step speed ref. cmd. B
1
3
Selection 3 (Terminal S3)
8
8: Multi-step speed ref. cmd. C
(0)
Drive Parameters - Continued
Section 9
Drive Parameter Listing
(n018-n052)