Yaskawa V7N Drive with DeviceNet User Manual
Page 33

33
When using the Monitor Function, a variety of information will appear on the Digital Operator
display when each of the U-XX (display only) parameters is selected.
Monitor
Contents
Display Example
MEMOBUS Address (hex)
U-01
Frequency reference (Hz)
60.0
23
U-02
Output frequency (Hz)
60.0
24
U-03
Output current (A)
12.5
3B
U-04
AC output voltage (V)
230
28
U-05
DC Bus voltage (VPN)
325
31
U-06
Multi-function input terminal and
2B
DeviceNet input status
U-07
Multi-function output terminal and
2D
DeviceNet output status
U-08
Motor torque (%)
72
32
(Open loop vector only)
U-09
Fault history
1.bUS
1B2
(last 4 faults)(1)
U-10
Software number
0010
1B3
XXXX
U-11
Output power (KW)
99.9
37
U-12
Reserve (Not displayed)
-
-
U-13
(2)
Elapse time
1234
35
(0-6550 (x 10hour))
U-14
Reserve (N/A)
-
-
U-15
Reserve (N/A)
-
-
U-16
PID feedback (%)
35.0
38
U-17
PID input (%)
100
39
U-18
PID output (%)
75.5
3A
U-19
Reserve (Not displayed)
-
-
U-60
DeviceNet Polled Producing
70: Basic speed control
-
Attribute (PPA)
71: Extended Speed Control
(Readable via DeviceNet Object Class
150: V7N Memobus I/O Control
5, Instance 2, Attribute 10)
151: V7N Standard Drive Control
152: V7N Accel/Decel Time Control
155: V7N Extended I/O MEMOBUS
Instance
156: V7N General Purpose DI/DO
Instance
U-61
DeviceNet Polled Consuming
20: Basic speed control
-
Attribute (PCA)
21: Extended Speed Control
(Readable via DeviceNet Object Class
100: V7N Memobus I/O Control
5, Instance 2, Attribute 10)
101: V7N Standard Drive Control
102: V7N Accel/Decel Time Control
105: V7N Extended I/O MEMOBUS
Instance
106: V7N General Purpose DI/DO
Instance
U-62
DeviceNet MAC ID switch setting
17
-
(S3 x 10 + S4)
U-63
DeviceNet MAC ID set
17
-
(Readable via DeviceNet Object Class
3, Instance 1, Attribute 1)
U-64
DeviceNet Baud Rate switch setting
1
-
(S1)
U-65
DeviceNet Baud Rate set
125: 125 kbps
-
(when in Auto Baud)
250: 250 kbps
(Readable via DeviceNet Object Class
500: 500 kbps
3, Instance 1, Attribute 2)
U-66
DeviceNet connection status
-
(Readable via DeviceNet Object Class
5, Instance 1 and 2, Attribute 1)
(1)
(1)
(1)
(1) Refer to TM.V7N.01 for Monitor details
(2) Available only in CIMR-V7NU25P5, 27P5, 45P5, and 47P5 Drives
Section 10
Monitor Displays