Drive parameters - continued – Yaskawa V7N Drive with DeviceNet User Manual

Page 28

Advertising
background image

28

PARA- ADDR CLASS 100

NAME

DATA

SETTING RANGE

SETTING

FACTORY

METER

INST. 01

(AND UNITS)

INCREMENT SETTING

9

9:

Multi-step speed ref. cmd. D

n053 135h

35h

Multi-function Input Selection 4

Ah

10: JOG Selection

1

5

(Terminal S4)

Bh

11: Accel/Decel time change cmd.

(5)

Ch

12: External Base Block (N.O.)

n054 136h

36h

Multi-function Input Selection 5

Dh

13: External Base Block (N.C.)

1

6

(DeviceNet Input S5)

Eh

14: Speed search from max. freq.

(6)

Multi-function Input Selection 6

Fh

15: Speed search from set freq.

n055 137h

37h

(DeviceNet Input S6)

10h

16: Accel/Decel hold command

1

7

11h

17: Remote/Local selection

(7)

12h

18: Communication / control circuit terminal

selection

13h

19: Fast Stop - Fault (N.O.)

14h

20: Fast Stop - Alarm (N.O.)

15h

21: Fast Stop - Fault (N.C.)

Multi-function Input Selection 7

16h

22: Fast Stop - Alarm (N.C.)

1

10

n056 138h

38h

(DeviceNet Input S7)

17h

23: PID control off

(10)

18h

24: I value reset (PID)

19h

25: I value hold (PID)

1Ah

26: Over Heat Pre-alarm OH3

1Bh

27: Accel/Decel Time Select 2

1Ch 28: Data input from DeviceNet communications

22

34: Up/Down Function

0

0:

Fault

Multi-Function Output

1

1:

During running

n057 139h

39h

Selection 1 (DeviceNet

2

2:

Speed Agree

1

0

Output MA)

3

3:

Zero Speed

4

4:

Frequency detection 1

5

5:

Frequency detection 2

6

6:

Overtorque detection (N.O.)

7

7:

Overtorque detection (N.C.)

Multi-Function Output

8

8:

Undertorque Detection (N.O.)

n058 13Ah

3Ah

Selection 2

9

9:

Undertorque Detection (N.C.)

1

1

(Terminals P1 & PC)

Ah

10: Minor Fault

Bh

11: During Base Block

Ch

12: Local / Remote

Dh

13: Ready

Eh

14: During auto restart

Fh

15: During undervoltage

Multi-Function Output

10h

16: During reverse run

n059 13Bh

3Bh

Selection 3

11h

17: During speed search

1

2

(Terminals P2 & PC)

12h

18: Comm. Controlled

13h

19: PID feedback loss

14h

20: Frequency Reference Loss Detect (N.O.)

15h

21: Overheat Pre-alarm OH3 (N.O.)

n064 140h

40h

Frequency Reference Loss

0

0:

No Detection

1

0

Detection

1

1:

Continue to run at 80% of max. frequency

n068 144h

44h

Analog Frequency Reference

-

-255 to 255

1%

100

Gain (CN2, Voltage Ref Input)

n069 145h

45h

Analog Frequency Reference

-

-100 to 100

1%

0

Bias (CN2, Voltage Ref Input)

Drive Parameters - Continued

Section 9

Drive Parameter Listing
(n053-n069)

IG.V7N.qxd:IG.V7N.qxd 6/5/07 3:22 AM Page 28