6.11 Manual Offset-Signal Adjustment of the Motor Current Detection Signal (Fn00F)

6-21

6

Util

ity Fu

nctions (Fn

)

Repeat the operations of steps 4 to 6 (phase-U and-V alternately) until adjusting the offset amounts both for
phase-U and -V in both directions cannot reduce the torque ripple any more.
Then, perform the same operation by adjusting by smaller amount.

7

Press the

Key to save the result of adjustment in

the SERVOPACK.
When the saving is completed, the status display
shows "DONE" for one second. The status display
then returns to show "RUN" again.

8

Press the

Key.

The display returns to the main menu of the utility

function.

(cont’d)

Step

Display after Operation

Keys

Operation

R U N
M a n u a l O f f s e t

− A D J

o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 1 6

R U N

− F U N C T I O N −

F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r