10.1 List of Parameters

10-9

10

Ap

pend

ix

Pn10B

2

Application Function for
Gain Select Switch

0000 to 5334

0000

Pn10C

2

Mode Switch (torque refer-
ence)

0 to 800

1%

200

Immediately

Tuning

5.9.2

Pn10D

2

Mode Switch (speed refer-
ence)

0 to 10000

1 min

-1

0

Immediately

Tuning

Pn10E

2

Mode Switch (acceleration)

0 to 30000 1 min

-1

/ s

0

Immediately

Tuning

Pn10F

2

Mode Switch (position error)

0 to 10000

1

reference

unit

0

Immediately

Tuning

Pn11F

2

Position Integral Time
Constant

0 to 50000

0.1 ms

0

Immediately

Tuning

5.9.4

Pn121

2

Friction Compensation Gain

10 to 1000

1%

100

Immediately

Tuning

5.8.2

Pn122

2

2nd Gain for Friction
Compensation

10 to 1000

1%

100

Immediately

Tuning

Pn123

2

Friction Compensation
Coefficient

0 to 100

1%

0

Immediately

Tuning

Pn124

2

Friction Compensation
Frequency Correction

-10000 to

10000

0.1 Hz

0

Immediately

Tuning

Pn125

2

Friction Compensation Gain
Correction

1 to 1000

1%

100

Immediately

Tuning

Pn131

2

Gain Switching Time 1

0 to 65535

1 ms

0

Immediately

Tuning

5.8.1

Pn132

2

Gain Switching Time 2

0 to 65535

1 ms

0

Immediately

Tuning

Pn135

2

Gain Switching
Waiting Time 1

0 to 65535

1 ms

0

Immediately

Tuning

Pn136

2

Gain Switching
Waiting Time 2

0 to 65535

1 ms

0

Immediately

Tuning

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

Mode Switch Selection

When

Enabled

Classification

Reference

Section

0

Uses internal torque reference as the condition
(Level setting: Pn10C).

Immediately

Setup

5.9.2

1

Uses speed reference as the condition (Level
setting: Pn10D).

2

Uses acceleration as the condition (Level setting:
Pn10E).

3

Uses position error as the condition (Level setting:
Pn10F).

4

No mode switch function available.

Speed Loop Control Method

When

Enabled

Classification

Reference

Section

0

PI control

After restart

Setup

1

I-P control

2 to 3

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.