Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors MECHATROLINK-III Communications Reference User Manual

Page 372

Advertising
background image

10.1 List of Parameters

10-41

10

Ap

pend

ix

89

PnB12

4

Monitor Selection for SEL_MON1
(CMN1)

0 to 6

0

Immedi-

ately

Command

Related

Parameters

0000H

TPOS (Target position in the reference coordinates)

0001H

IPOS (Reference position in the reference coordinates)

0002H

POS_OFSET (Offset value set in the set coordinates command
(POS_SET))

0003H

TSPD (Target speed)

0004H

SPD_LIM (Speed limit value)

0005H

TRQ_LIM (Torque limit value)

0006H

SV_STAT
Monitor

Byte 1: Current communications phase

00H: Phase 0
01H: Phase 1
02H: Phase 2

03H: Phase 3

Byte 2: Current control mode

00H: Position control mode
01H: Speed control mode
02H: Torque control mode

Byte 3: Reserved
Byte 4: Expansion signal monitor

(cont’d)

Parameter

No.

Size

Name

Setting Range

Units

[Resolution]

Factory

Setting

When

Enabled

Classifica-

tion

Bit

Name

Contents

Value

Setting

Bit 0 LT_RDY1

Processing status
for latch detection
specified by
SVCMD_CTRL,
LT_REQ1

0

Latch
detection not
processed

1

During latch
detection
processing

Bit 1 LT_RDY1

Processing status
for latch detection
specified by
SVCMD_CTRL,
LT_REQ2

0

Latch
detection not
processed

1

During latch
detection
processing

Bit 2,
Bit 3

LT_SEL1R Latch signal

0

Phase C

1

External
input signal 1

2

External
input signal 2

3

External
input signal 3

Bit 4,
Bit 5

LT_SEL2R Latch signal

0

Phase C

1

External
input signal 1

2

External
input signal 2

3

External

input signal 3

Bit 6 Reserved (0)