8.3 Parameter Settings for Fully-closed Loop Control

8-19

8

Fu

lly-close

d L

oop

Co

ntro

l

(3) Serial Data Specifications

The serial data is output from the PAO signal.

(4) Transferring Alarm Contents

If an external absolute encoder is used, the contents of alarms detected by the SERVOPACK are transmitted in

serial data to the host controller from the PAO output when the Turn Sensor OFF command (SENS_OFF) is

received.

Note: The SENS_OFF command cannot be received while the servomotor power is ON.

Output example of alarm contents are as shown below.

Data Transfer

Method

Start-stop Synchronization (ASYNC)

Baud rate

9600 bps

Start bits

1 bit

Stop bits

1 bit

Parity

Even

Character code

ASCII 7-bit code

Data format

8 characters, as shown below.

Note: 1. Data is "P+00000" (CR) or "P-00000" (CR) when the position is zero.

2. The serial data range is "-32768" to "+32767". When this range is exceeded, the data

changes from "+32767" to "-32678" or from "-32768" to "+32767." When changing
multiturn limit, the range changes. For details, refer to 4.7.6 Multiturn Limit Setting.

Data

Start bit

Even parity

serial data
in five digits

"+" or " - "

"0" to "9"

"CR"

"P"

Stop bit

0 0 0 0 0 1 0 1 0 1

OFF

Error detection

ON

Incremental pulse

Serial Data

Enlarged view

Turns Sensor
OFF
(SENS_OFF)

Panel Display

PAO Output

Serial Data Format

Upper 2 digits

A

L

M

5

1

.

CR

" "

" "

" "

" "

" "

" " "

"

or

Overspeed

64