This section provides the specification of the serial converter unit.

(1) Model: JZDP-D00 -

-E

Characteristics and Specifications

* 1. The current consumption of the external encoder is not included in this value.

The current consumption of the external encoder must be taken into consideration for the current
capacity of host controller that supplies the power.

* 2. Input a value within the specified range. Otherwise, incorrect position information is output, and the

device may be damaged.

* 3. The transmission is enabled 100 to 300 ms after the power turns ON.

Items

Specifications

Electrical

Characteristics

Power Supply Voltage

+5.0 V

±5%, ripple content 5% max.

Current Consumption

∗1

120 mA Typ. 350 mA max.

Signal Resolution

1/256 pitch (1 cycle) of input 2-phase sine wave pitch

Max. Response Frequency

250 kHz

Analog Input Signals

∗2

(cos, sin, Ref)

Differential input amplitude: 0.4 V to 1.2 V
Input signal level: 1.5 V to 3.5 V

Output Signal

∗3

Position data, alarms

Output Method

Serial data communications

Output Circuit

Balanced type transceiver (SN75LBC176 or the equivalent),
internal terminating resistor: 120

Ω

Mechanical

Characteristics

Approx. Mass

150 g

Vibration Resistance

98 m/s

2

max. (10 to 2500 Hz) in three directions

Shock Resistance

980 m/s

2

, (11 ms) two times in three directions

Environmental

Conditions

Surrounding air Temperature

0

°C to 55 °C

Storage Temperature

-20

°C to +80 °C

Humidity

20% to 90%RH (without condensation)

Altitude

1000 m max.