9.1 Alarm Displays

9-19

9

Trou

blesh

ooting

A.d00:
Position Error Over-

flow
(Position error exceeded

the value set in the

excessive position error

alarm level (Pn520).)

The servomotor U, V, and W wir-

ings is faulty.

Check the servomotor main circuit

cable connection.

Confirm that there is no contact

fault in the motor wiring or encoder

wiring.

The position reference speed is

too high.

Reduce the reference speed, and

operate the SERVOPACK.

Reduce the position reference speed

or acceleration of position refer-

ence. Or, reconsider the electronic

gear ratio.

The acceleration of the position

reference is too high.

Reduce the reference acceleration,

and operate the SERVOPACK.

Reduce the reference acceleration

of the position reference using a

MECHATROLINK command, or

smooth the acceleration of the posi-

tion reference by selecting the posi-

tion reference filter (ACCFIL)

using a MECHATROLINK com-

mand.

Setting of the excessive position

error alarm level (Pn520) is low

against the operating condition.

Check the alarm level (Pn520) to

see if it is set to an appropriate

value.

Set the Pn520 to proper value.

A SERVOPACK fault occurred.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the SERVOPACK may be

faulty. Replace the SERVOPACK.

A.d01:
Position Error Over-

flow Alarm at Servo

ON

This alarm occurs if the servomo-
tor power is turned ON when the
position error is greater than the
set value of Pn526 while the ser-
vomotor power is OFF.

Check the position error amount

(Un008) while the servomotor

power is OFF.

Correct the excessive position error

alarm level at servo ON (Pn526).

A.d02:
Position Error Over-

flow Alarm by Speed

Limit at Servo ON

When the position errors remain
in the error counter, Pn529 limits
the speed if the servomotor power
is ON. If Pn529 limits the speed
in such a state, this alarm occurs
when position references are
input and the number of position
errors exceeds the value set for
the excessive position error alarm

level (Pn520).

Correct the excessive position error

alarm level (Pn520).
Or, adjust the speed limit level at

servo ON (Pn529).

A.d10:
Motor-load Position

Error Overflow

Motor rotation direction and

external encoder installation

direction are opposite.

Check the servomotor rotation

direction and the external encoder

installation direction.

Install the external encoder in the

opposite direction, or change the

setting of the external encoder

usage method (Pn002.3) to reverse

the direction.

Mounting of the load (e.g., stage)

and external encoder joint instal-

lation are incorrect.

Check the external encoder

mechanical connection.

Check the mechanical joints.

A.E02:
MECHATROLINK
Internal Synchroniza-

tion

Error 1

MECHATROLINK transmission
cycle fluctuated.

Remove the cause of transmission

cycle fluctuation at host controller.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E40:
MECHATROLINK

Transmission Cycle

Setting Error

Setting of MECHATROLINK
transmission cycle is out of speci-
fications range.

Check the MECHATROLINK
transmission cycle setting.

Set the transmission cycle to the
proper value.

A.E41:
MECHATROLINK

Communications Data

Size Setting Error

The number of transmission bytes
set by the DIP switch S3 is incor-
rect.

Check the MECHATROLINK com-
munications data size of the host
controller.

Reset the setting of the DIP switch
S3 to change the number of trans-
mission bytes to the proper value.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions