17

Hardware Overview

AC Power Supply Specifications

The following table lists the specifications for the X-Pedition’s AC power supplies.

To ensure against equipment failure, you can install a redundant power supply. When two power
supplies are active in the X-Pedition, they load share, each supply delivering approximately 50
percent of the current needed. Moreover, if one of the power supplies fails, the other power supply
immediately assumes the entire load, thus preventing any system outage.

The AC power supply has a green status LED. When the LED is lit, the power supply is connected
to an appropriate power source and is active. The status LED is lit when you switch the power
supply on, not when you plug the power supply into a power source.

X-Pedition 8000

X-Pedition 8600

Dimensions

8.27 in. H x 17.25 W x 12.25 D
22.23 cm H x 43.82 W x 31.12 D

8.27 in. H x 17.23 W x 19.25 D
22.23 cm H x 43.82 W x 48.9 D

Weight

Pounds: 24Lbs
Kilograms: 10.8 Kg

Pounds: 47 Lbs
Kilograms: 21.2 Kg

AC Power

100-125 VAC, 5A maximum
200-240 VAC, 3A maximum
50/60 Hz

100-125 VAC, 10A maximum
200-240 VAC, 6A maximum
50/60 Hz

Output Wattage

At 3.4 V
At 5.1 V
At 12 Volts

390 Watts

70 Amps
25 Amps
2 Amps

780 Watts

140 Amps
50 Amps
4 Amps

Operating
Temperature

Fahrenheit: 41

o

F to 104

o

F

Centigrade: 5

o

C to 40

o

C

Fahrenheit: 41

o

F to 104

o

F

Centigrade: 5

o

C to 40

o

C