Dc power supply installation procedure – Enterasys Networks 8000/8600 User Manual

Page 73

Advertising
background image

Enterasys X-Pedition 8000/8600 Getting Started Guide

61

Installing the Hardware

The following table lists the environmental specifications for the X-Pedition’s DC power supplies.

DC Power Supply Installation Procedure

To install a DC power supply on the X-Pedition 8000 or X-Pedition 8600:

1.

Ensure that the DC power supply is not powered on.

2.

If a coverplate is installed over the DC power supply slot, use a #2 Phillips screwdriver to
remove it. If you are replacing a power supply, unplug the power cable from the supply you are
replacing, loosen the captive screws on the power supply’s front panel, then pull the supply out
of the chassis.

3.

Slide the DC power supply all the way into the slot, firmly but gently pressing to ensure that
the pins on the back of the power supply are completely seated in the backplane.

4.

Use a #2 Phillips screwdriver to tighten the captive screws on each side of the DC power
supply to secure it to the chassis.

5.

Attach wires to the terminal blocks on the front of the unit. To attach a wire, loosen the
terminal screw, insert the exposed end of the wire, and tighten the terminal screw.

6.

Connect the safety ground wire to a reliable earth ground.

7.

Connect the DC input wiring to a DC power source. See

Figure 28 on page 64

and

Figure 29

on page 64

for a diagram of the wiring connections between the X-Pedition and a DC power

source.

Operating Temperature

+5 to +40 °C (41 to 104 °F)

Non-operating Temperature

-30 to +73 °C (-22 to 164 °F)

Operating Humidity

15 to 90% (non-condensing)

Advertising