23

Hardware Overview

Ports

Depending on the APHY used, 1 or 2.

APHY-92V

1 E-1 interface (UTP); see APHY-82V

on page 81

for attaching

cables

Note:

The APHY-92V is not an E1 interface. It merely allows you
to connect to an E1 CSU—the E1 CSU will allow you to
connect to an E1 circuit.

ITU-T G.703 for a symmetrical pair

120 ohm symmetrical pair

Maximum of 655 ft (200 m) of cable

0 through 6 dB loss at 200 m

APHY-21

1 OC-3c MMF interface (SC-style); see APHY-21 and APHY-
29IR

on page 81

for attaching cables

EIA/TIA 492-AAAA

62.5/125 µm

Maximum cable length cannot exceed 2 kilometers (maximum
will allow up to three cables—two splices). Additional
cables/splices will reduce the maximum cable length.

0 to 9 dB loss at 1300 nm

APHY-29IR

1 OC-3c SMF-IR interface (SC-style); see APHY-21 and APHY-
29IR

on page 81

for attaching cables

EIA/TIA 492-CAAA

9/125 µm

Maximum cable length cannot exceed 15 kilometers (maximum
will allow up to three cables—two splices). Additional
cables/splices will reduce the maximum cable length.

0 to 15 dB loss at 1300 nm

APHY-22

1 OC-3c interface (UTP); see APHY-22

on page 82

for attaching

cables

EIA/TIA 568B

295 ft (90 m) of Category 5 building cable

33 ft (10 m) of Category 5 patch cords

1 punchdown block (Category 5)

APHY-92V

PHY

APHY-21

PHY

APHY-29IR

PHY

APHY-22

PHY