Firmware image requirements, Installing a memory upgrade – Enterasys Networks 8000/8600 User Manual

Page 78

Advertising
background image

Installing the Hardware

66

Enterasys X-Pedition 8000/8600 Getting Started Guide

Firmware Image Requirements

Version 8.2.0.0 or later.

Default Module Settings

The CM4 comes with the baud rate on RS232 console port set to 9600.

Preparing the Module

You must install the PCMCIA card before you install the command module. You cannot add or
remove a PCMCIA card while the unit is powered on.

Installing a Memory Upgrade

1.

Determine how much memory is already installed on the Control Module. If you do not
know how much memory is installed on the Control Module, enter the system show hardware
command in Enable mode. The amount of memory is reported as the System Memory size. For
example:

2.

Power down the chassis.

Note:

If the X-Pedition chassis contains a redundant Control Module, you do not need to power
down the X-Pedition. You must, however, press the Hot Swap button before removing the
Control Module.

CAUTION: Before performing any upgrade or installation, ensure that you are properly
“grounded” to avoid electrostatic discharge. The switch must be powered off before
installing or replacing any module.

xp# system show hardware

Hardware Information:

System type:

X-Pedition 8600, Rev. A

CPU Module type:

CPU-Elan, Rev. 0

Processor:

R5000, Rev 3.0, 249.99 MHz

Icache size:

32 Kbytes, 32 bytes/line

Dcache size:

32 Kbytes, 32 bytes/line

CPU Board Frequency:

83.33 MHz

Switching Fabrics:

2 (Active = Fabric 1)

PCMCIA card:

No card present

System Memory size:

64 MBytes

Network Memory size:

8 MBytes

MAC Addresses

System: 00e063:fdd700
10BASE-T CPU Port:00e063:fdd701
Internal Use:

00e063:fdd702 -> 00e063:fdd73f

CPU Mode:

Active

Redundant CPU:

Not present

Advertising