Default module settings, Cli setup, Proper boot sequence – Enterasys Networks 8000/8600 User Manual

Page 86: Common errors, Helpful cli commands for debugging

Advertising
background image

Installing the Hardware

74

Enterasys X-Pedition 8000/8600 Getting Started Guide

SSR-GTX32-04
SSR-GTX32-02

9.0.0.0

Note: The SSR-GTX32-02 line card does not

support 10/100 Mbps traffic.

Default Module Settings

The default mode for each port on the
X-Pedition 8000/8600X-Pedition is:

Full duplex/ 1000 mbs/ autonegotiation on

To view the current mode for a particular port, enter
the following (where x is the chassis slot that
contains the line card and y is a specific port number
on the card):

xp# port show port status gi.x.y

CLI Setup

Enter the following commands at the CLI before
implementing any configurations.

1.

Enable —> Configure —> <Enter>.

2.

Once you reach the configuration prompt, you
can configure the module

using CLI commands

as described in the X-Pedition CLI manual.
Enter the ? character to view the options
available to you in configuration mode.

Proper Boot Sequence

•

Offline LED lights at power-up.

•

Port LEDs flicker briefly during system boot while
ports initialize.

•

Online LED turns on once module is active.

Common Errors

•

The X-Pedition is not powered up.

•

The module is not properly seated in the slot.

•

Connectors on both ends of the cable are not properly
engaged. The copper cable did not click into place or
is not properly seated.

Helpful CLI Commands for Debugging

•

System show hardware

•

System show version

•

System show bootlog

SSR-HSSI-02-CK

8.3.0.0

CLI Setup

Enter the following command at the CLI before
implementing any configurations.

1.

Type the following from Enable mode to enter
Configuration mode
Enable -> Configure #

2.

You may now begin configuring ports on the
SSR-HSSI-02-CK. Refer to the Enterasys
X-Pedition Command Line Interface Reference
Manual
for details.

Proper Boot Sequence

•

Firmware loads.

•

The control module for the chassis should indicate
that the SSR-HSSI-02-CK was detected and is
operating correctly.

•

The Online LED will turn on and remain lit (no other
LEDs should illuminate during module power-up).

Common Errors

•

The SSR-HSSI-02-CK is not inserted properly or
seated completely in the chassis

•

Connectors for the connected lines are not seated
properly.

•

The CM does not connect to a terminal through a
console port.

Helpful CLI Commands for Debugging

•

System show hardware

•

System show version

•

Port show port status gi.x.y (where x is the chassis
slot that contains the line card and y is a specific port
number on the card).

•

System show boot log

Table 19. Line card installation notes (Continued)

Minimum
Firmware

Restrictions

Special Instructions