Default module settings, Cli setup, Proper boot sequence – Enterasys Networks 8000/8600 User Manual

Page 86: Common errors, Helpful cli commands for debugging

Advertising
background image

Installing the Hardware

74

Enterasys X-Pedition 8000/8600 Getting Started Guide

SSR-GTX32-04
SSR-GTX32-02

9.0.0.0

Note: The SSR-GTX32-02 line card does not

support 10/100 Mbps traffic.

Default Module Settings

The default mode for each port on the
X-Pedition 8000/8600X-Pedition is:

Full duplex/ 1000 mbs/ autonegotiation on

To view the current mode for a particular port, enter
the following (where x is the chassis slot that
contains the line card and y is a specific port number
on the card):

xp# port show port status gi.x.y

CLI Setup

Enter the following commands at the CLI before
implementing any configurations.

1.

Enable —> Configure —> <Enter>.

2.

Once you reach the configuration prompt, you
can configure the module

using CLI commands

as described in the X-Pedition CLI manual.
Enter the ? character to view the options
available to you in configuration mode.

Proper Boot Sequence

Offline LED lights at power-up.

Port LEDs flicker briefly during system boot while
ports initialize.

Online LED turns on once module is active.

Common Errors

The X-Pedition is not powered up.

The module is not properly seated in the slot.

Connectors on both ends of the cable are not properly
engaged. The copper cable did not click into place or
is not properly seated.

Helpful CLI Commands for Debugging

System show hardware

System show version

System show bootlog

SSR-HSSI-02-CK

8.3.0.0

CLI Setup

Enter the following command at the CLI before
implementing any configurations.

1.

Type the following from Enable mode to enter
Configuration mode
Enable -> Configure #

2.

You may now begin configuring ports on the
SSR-HSSI-02-CK. Refer to the Enterasys
X-Pedition Command Line Interface Reference
Manual
for details.

Proper Boot Sequence

Firmware loads.

The control module for the chassis should indicate
that the SSR-HSSI-02-CK was detected and is
operating correctly.

The Online LED will turn on and remain lit (no other
LEDs should illuminate during module power-up).

Common Errors

The SSR-HSSI-02-CK is not inserted properly or
seated completely in the chassis

Connectors for the connected lines are not seated
properly.

The CM does not connect to a terminal through a
console port.

Helpful CLI Commands for Debugging

System show hardware

System show version

Port show port status gi.x.y (where x is the chassis
slot that contains the line card and y is a specific port
number on the card).

System show boot log

Table 19. Line card installation notes (Continued)

Minimum
Firmware

Restrictions

Special Instructions