Installing the Hardware

Installing Line Cards

You can install line modules in slots 1 to 7 on the X-Pedition 8000 (slot 0 allows a control module
only) or 1 to 15 on the X-Pedition 8600 (again, slot 0 allows a control module only). If you plan to
install a redundant control module, you may install line cards in slots 2–7 on the X-Pedition 8000
and 2–15 on the X-Pedition 8600. Before you begin, please review

Table 19

for system firmware

requirements, restrictions, and special instructions that apply to the line card you are installing.

ELECTRICAL HAZARD: Only qualified personnel should perform installation procedures.

Table 19. Line card installation notes

Minimum
Firmware

Restrictions

Special Instructions

SSR-ARE

Note: The SSR-ARE is designed for the

X-Pedition 8000/8600 only—do not try to
install these modules in any other units. Do
not install the SSR-ARE in slot 0 or 1 on the
X-Pedition 8000 or slot 0, 1, or 15 on the
X-Pedition 8600.

SSR-ATM29-02

3.0.0.0

CLI Setup

Enter the following commands at the CLI before
implementing any configurations.

1.

Enable —> Configuration —> <Enter>.

2.

Once you reach the configuration prompt, you
can create the ATM interface using CLI
commands as described in the ATM section of
the X-Pedition CLI manual. Enter the ?
character to view the options available to you in
configuration mode.

Proper Boot sequence

The control module on the chassis should indicate
that the SSR-ATM29-02 was detected and is
operating correctly.

Common Errors

Make sure the chassis is connected to a terminal
through a console port.

Helpful CLI Commands for Debugging

System show hardware

System show version

System show bootlog