Preparing the module, Default module settings, Cli setup – Enterasys Networks 8000/8600 User Manual

Page 85: Proper boot sequence, Common errors, Helpful cli commands for debugging

Advertising
background image

Enterasys X-Pedition 8000/8600 Getting Started Guide

73

Installing the Hardware

SSR-GLX39-04
SSR-GSX31-04

8.3.0.0

Note: If your system uses a redundant power

configuration or only one power supply, you
will not be able to support more than 5 SSR-
GLX39-04 and SSR-GSX31-04 cards in the
X-Pedition 8000 and 10 in the
X-Pedition 8600.

Note: You may install the SSR-GLX39-04 or

SSR-GSX31-04 in any line card slot except
the CM slot which supports a control module
only.

Preparing the Module

•

When connecting a 1000Base-SX/LX module to
a device that does not support auto-negotiation,
ensure that auto-negotiation is disabled and that
both devices are set to the same data transmission
speed and duplex mode.

Default Module Settings

The default mode for each port on the X-Pedition-
8000 and X-Pedition-8600 is:

Full duplex/ 1000 mbs/ autonegotiation on

To view the current mode for a particular port, enter
the following (where x is the chassis slot that
contains the line card and y is a specific port number
on the card):

xp# port show port status gi.x.y

CLI Setup

Enter the following commands at the CLI before
implementing any configurations.

1.

Type the following from Enable mode to enter
Configuration mode
Enable -> Configure #

2.

You may now begin configuring ports on the
SSR-GLX39-04 or SSR-GSX31-04. Refer to the
Enterasys X-Pedition Command Line Interface
Reference Manual
for details.

When connecting a 1000BASE-SX/LX module to a
device that does not support auto-negotiation, ensure that
Auto-Negotiation is disabled and that both devices are set
to the same data transmission speed and duplex mode.

Proper Boot Sequence

•

Offline LED turns on and remains on until card is
online.

•

Port LEDs turn on momentarily and the CLI indicates
that the system discovered the line card in proper slot.

•

CLI indicates all ports are initialized and offline LED
turns off.

•

Online LED lights.

•

Link LED is active for connected lines.

Common Errors

•

The line card is not inserted properly or seated
completely in the chassis

•

Connectors for the connected lines are not seated
properly.

•

Attached device is not configured to match
configuration mode of module (i.e., auto-negotiation,
speed, duplex).

Helpful CLI Commands for Debugging

•

System show hardware

•

System show version

•

Port show port status gi.x.y (where x is the chassis
slot that contains the line card and y is a specific port
number on the card).

•

System show bootlog

Table 19. Line card installation notes (Continued)

Minimum
Firmware

Restrictions

Special Instructions

Advertising