X-Pedition 8000 DC Power Supply

Figure 25

shows the front view of an X-Pedition 8000 DC power supply.

Figure 25. Front view of an X-Pedition 8000 DC power supply

The X-Pedition 8000 DC power supply has a three-terminal wiring block on the front panel,
consisting of a positive (+) terminal, negative (-) terminal and a safety ground. The DC supply is
designed to be powered by a 48-volt DC source.

X-Pedition 8600 DC Power Supply

Figure 26

shows the front view of an X-Pedition 8600 DC power supply.

Figure 26. Front view of an X-Pedition 8600 DC power supply

The X-Pedition 8600 DC power supply has a five-terminal wiring block on the front panel. The
wiring block contains two positive (+) terminals, two negative (-) terminals, and a safety ground.
The DC supply is designed to be powered by a 48-volt DC source.

SSR-PS-8-DC

PWR

SN

!

To be installed in a restricted
access area in accordance
with the NEC or authority
having jurisdiction.

See manual for installation
instructions.

48/60V
14A MAX

PWR

SSR-PS-16-DC

SN

48/60V
27A MAX

!

To be installed in a restricted
access area in accordance
with the NEC or authority
having jurisdiction.

See manual for installation
instructions.