Rose Electronics UltraConsole Remote 2 User Manual

Page 52

Advertising
background image

46

ULTRACONSOLE REMOTE 2 INSTALLATION AND OPERATIONS MANUAL

Option 4. Send this Unit’s Main Program to other Units.
Option 5. Send this Unit’s Kernel to other Units.
The main program or kernel program updates (Option 3) only have to be done on one port. Make sure power to all
UltraConsole Remote 2 switches is “ON” and they are all connected using the appropriate expansion cables.

Press 4 to send the main program to all other units, all other cards.
Press 5 to send the kernel program to all other cards.
The following messages will appear using either option 4 or option 5.

Before responding Y, make sure that the “Boards to update” number in the message above agrees with the total
number of boards in the entire system minus 1. If the number does not agree, reply N, turn on the inactive
UltraConsole Remote 2 Units, and press 4 or 5 again. When you reply Y, the following message appears:



When complete, the system returns you to the serial options menu. Wait at least 15 seconds before restarting the
UltraConsole Remote 2 after choosing option 4 or 5 for the program to propagate to the other cards in the system.

Option 6. Reset to Factory Defaults (This CPU card only)
NOTE: Before resetting any CPU card to factory defaults, note the starting computer number listed on the Serial
menu, Option 1. When resetting a CPU card to factory defaults, this number will be set to one (1) and must be
changed back to the original value by using option 1 and then saved using option 7. In an expanded system, there
cannot be two different UltraConsole Remote 2 switches in the system with the same starting computer number.

Selecting option 6 restores the CPU card to its original factory configuration. The following message appears:



When the flash memory is updated, the following message is displayed:



Option 8. Exit (Restart the Unit)
Selecting option 8 exits the serial option menu. The UltraConsole Remote 2 switch will reinitialize and the diagnostic
check will run. After the diagnostic check finished, the Unit is ready to use with its new configurations. If there are
more configurations needed, hit the space bar within 5 seconds and the serial menu will be brought back up to use.




















Sending flash program code to system........................

Flash programming . . . . . . . . . . . . . . . . . . . .

Configuration saved successfully