Class code, Revision id, 0x08 – Avago Technologies LSI8751D User Manual

Page 81: Register: 0x08, Register: 0x09

Advertising
background image

Configuration Registers

3-17

Register: 0x08

Revision ID
Read Only

RID

Revision ID

[7:0]

This register specifies device and revision identifiers. The
value of the LSI53C875E is 0x26 and 0x0 for the
LSI53C875.

Register: 0x09

Class Code
Read Only

CC

Class Code

[23:0]

This 24-bit register is used to identify the generic function
of the device. The upper byte of this register is a base
class code, the middle byte is a subclass code, and the
lower byte identifies a specific register level programming
interface. The value of this register is 0x010000, which
indicates a SCSI controller.

7

0

RID

LSI53C875E

0

0

1

0

0

1

1

0

LSI53C875

0

0

0

0

0

1

0

0

23

0

CC

0

0

0

0

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0