2 status – PLANET MGSD-10080F User Manual

Page 328

Advertising
background image

User’s Manual of MGSD-10080F

328

604800 seconds (7 days). A value of zero will keep a port disabled (until next

device restart).

Port Configuration:

Object

Description

•

Port

The switch port number of the port.

•

Enable

Controls whether loop protection is enabled on this switch port.

• Action

Configures the action performed when a loop is detected on a port. Valid values

are Shutdown Port, Shutdown Port and Log or Log Only.

• Tx Mode

Controls whether the port is actively generating loop protection PDU's, or

whether it is just passively looking for looped PDU's.

Buttons

: Click to save changes.

:

Click to undo any changes made locally and revert to previously saved values.

4.16.2 Status

This page displays the loop protection port status the ports from the Managed Switch.

Figure 4-16-2: Loop Protection Status Page Screenshot

The page includes the following fields:

Object

Description

•

Port

The switch port number of the logical port.

•

Action

The currently configured port action.

• Transmit

The currently configured port transmit mode.

• Loops

The number of loops detected on this port.

Advertising