Erps reversion, Erps vlan add – PLANET MGSD-10080F User Manual
Page 571

User’s Manual of MGSD-10080F
571
<east_port> : protection group Port 0
<west_port> : protection group Port 1, Port 1 can be 0 for sub-rings
[major|sub] : ring type i.e major-ring or sub-ring
[interconnected] : interconnection node or not
[[virtual_channel] : Virtual channel present or not
[<major-ring-id>] : major ring group Id for interconnected sub-ring
Syntax:
Erps add <group-id> <east_port> <west_port> [major|sub] [interconnected] [virtual_channel] [<major-ring-id>]
Parameters:
<group-id> : protection group id 1 - 64
<east_port> : Port 0 of a protection group
<west_port> : Port 1 of a protection group
major|sub : ring type
interconnected : Set for interconnected node
virtual_channel: Set for virtual channel
<major-ring-id>: major ring of a sub-ring, when configuring as an interconnected node
ERPS Reversion
Description:
Configuring reversion characteristics for a given node
[revertive|nonrevertive] : enabling or disabling reversion for a given group
<group_id> : protection group id
Syntax:
Erps reversion [revertive|nonrevertive] <group-id>
Parameters:
revertive|nonrevertive: specifying reversion parameters
<group-id> : protection group id 1 - 64
ERPS VLAN Add
Description:
Associating a given vlan to a protection group
<vid> : vlan to be protected