Erps reversion, Erps vlan add – PLANET MGSD-10080F User Manual

Page 571

Advertising
background image

User’s Manual of MGSD-10080F

571

<east_port> : protection group Port 0

<west_port> : protection group Port 1, Port 1 can be 0 for sub-rings

[major|sub] : ring type i.e major-ring or sub-ring

[interconnected] : interconnection node or not

[[virtual_channel] : Virtual channel present or not

[<major-ring-id>] : major ring group Id for interconnected sub-ring

Syntax:

Erps add <group-id> <east_port> <west_port> [major|sub] [interconnected] [virtual_channel] [<major-ring-id>]

Parameters:

<group-id> : protection group id 1 - 64

<east_port> : Port 0 of a protection group

<west_port> : Port 1 of a protection group

major|sub : ring type

interconnected : Set for interconnected node

virtual_channel: Set for virtual channel

<major-ring-id>: major ring of a sub-ring, when configuring as an interconnected node

ERPS Reversion

Description:

Configuring reversion characteristics for a given node

[revertive|nonrevertive] : enabling or disabling reversion for a given group

<group_id> : protection group id

Syntax:

Erps reversion [revertive|nonrevertive] <group-id>

Parameters:

revertive|nonrevertive: specifying reversion parameters

<group-id> : protection group id 1 - 64

ERPS VLAN Add

Description:

Associating a given vlan to a protection group

<vid> : vlan to be protected