COMMAND 55 - Write Transmitter Variable Damping Value

Description
This command writes the Damping Value of a user selected transmitter variable.

Write Parameters

Word

High Byte

Low Byte

0

Transmitter Variable Code

Transmitter Variable Damping Value (Byte

0)

1

Transmitter Variable Damping Value (Byte

1)

Transmitter Variable Damping Value (Byte

2)

2

Transmitter Variable Damping Value (Byte

3)

Transmitter Variable Damping Value (Byte

3)

Floating Point Data Returned

Word

High Byte

Low Byte

0

Transmitter Variable Damping Value

1

Integer Data Returned

Word

High Byte

Low Byte

0

STATUS WORD

1

Transmitter Variable Code

0