Ventilation Requirements

When mounting in an enclosed space or recessed area, leave adequate room between the monitor and the enclosure to allow
heat to disperse, as shown below.

100 mm

100 mm

100 mm

100 mm

30 mm

<40 °C

NOTEN:

• Allow adequate ventilation or provide air conditioning around the monitor, so that heat can properly dissipate away

from the unit and the mounting equipment; especially when you use monitors in a multiple screen configuration.

• This monitor has internal temperature sensors.

If the monitor overheats, a “Caution” warning appears. If the “Caution” warning appears, stop using the unit, turn off

the power and allow it to cool.

Mounting on Ceilings

WARNINGN:

Please refer to

“WARNING 8”

and

“WARNING 9”

.

Attaching Mounting Accessories

The monitor is designed for use with the VESA mounting system. Be careful to avoid tipping the monitor when attaching
accessories.

VESA Mounting Interface (M4)

100 mm

100 mm

Mounting Interface (M4)

200 mm

200 mm

Mounting accessories can be attached with the monitor in the face down position. To avoid scratching the LCD panel, always
place a soft cloth, such as a blanket that is larger than the monitor’s screen area, on the table before laying the monitor face
down. Make sure there is nothing on the table that can damage the monitor.

When using mounting accessories other than the one specified, they must comply with the VESA Flat Display Mounting
Interface Standard (FDMI).

NOTEN:

Prior to installation, place the monitor face down on a flat even surface that is larger than the monitor screen.
Use a sturdy table that can easily support the weight of the monitor.