SNMP Settings

Click on “SNMP” on the left-hand column below HOME.

The SNMP protocol is used to get status information and to control a monitor directly via the network.

VersionN:

SNMP v1

Authenticated plaintext by community name, does not return a confirmation message of the trap.

SNMP v2c

Authenticated plaintext by community name, returns a confirmation message of the trap.

Community nameN:

The default setting of community name is “public”. It is read-only. You can set community names for up to 3 settings.

TrapN:

Sending error message to a specified address when an error occurs in the monitor.

Check Box

Explanation

Error code

Temperature

Temperature abnormal

0xA0, 0xA1, 0xA2

Power

Power abnormal

0x70, 0x71, 0x72, 0x78

Inverter/Backlight

Inverter or backlight abnormal 0x90, 0x91

No Signal

No signal

0xB0

PROOF OF PLAY

Lower the log storage

0xD0

System Error

System error

0xE0

AMX Settings

Click on “AMX” on the left-hand column below HOME.

AMX BEACON

To turn on or off for the detection from AMX Device Discovery when connecting to a network
supported by an AMX’s NetLinx control system.
HINT:
When using a device that supports AMX Device Discovery, all AMX NetLinx control systems will
recognize the device and download the appropriate Device Discovery Module from an AMX server.
Selecting [ENABLE] AMX Device Discovery will detect the device.
Selecting [DISABLE] AMX Device Discovery will not detect the device.