Framing and clearances, Warning, 7100fp epa woodburning fireplace – Hearth and Home Technologies EPA Certified Woodburning Fireplace 7100FP-GD-B User Manual

Page 10: A. selecting fireplace location

Advertising
background image

Page 10

433-1390G

September 1, 2008

R

7100FP EPA Woodburning Fireplace

3

Framing and Clearances

A. Selecting Fireplace Location

Several options are available to you when choosing a loca-
tion for your fireplace. This fireplace may be used as a room
divider, installed along a wall, across a corner or used in an
exterior chase. See Figure 10.1.

Locating the fireplace in a basement, near frequently opened
doors, central heat outlets or returns, or other locations of

Figure 10.1 Fireplace Locations

Fire Risk

Provide adequate clearances.
• Around air openings
• To

combustibles

• For service access.

Locate fireplace away from traffic areas.

WARNING

Note:
Illustrations and photos reflect typical installations and

are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation/appearance may vary due to individual
design preference.

Hearth & Home Technologies reserves the right to alter

its products.

considerable air movement can affect the performance and
cause intermittent smoke spillage from the front of the fire-
place when no outside air is used. Outside air must be used
for combustion. The 7100FP comes equipped with an out-
side air inlet to feed combustion air from outside the home,
along with an outside air termination cap. Consideration
should be given to these factors before deciding on a loca-
tion. See Sections 2 and 10.

Model
#7100FP

(Dimensions for
finished walls)

A

B

C

D

E

F

G

H

I

in.

41-7/8

16

89-1/2

63-5/16 22-7/16 44-3/4 14-1/16 55-15/16 50-7/8

mm

1063

406

2273

1608

570

1137

357

1421

1292

D

C

A

E

F

A

H

G

B

A

B

B

A

I

In an exterior chase
or projecting into a
garage

Across a corner

Along a wall

As a
room
divider

24 in.

(610mm)

24 in.

(610mm)

24 in.

(610mm)

48 in.

(1219mm)

Note:

A minimum 1/2 in. air clearance must be maintained at the
back and 1 in. minimum clearance to the sides of the fireplace
assembly.

Chimney sections at any level require a 2 in. minimum air
space clearance between the framing and chimney sections.

Note:

In addition to these framing dimensions, also reference the
following sections:

Clearances (Section 3.B.)

Mantel (Section 8.F.)

Fireplace Dimensions (Section 12.A.)