Warning, 7100fp epa woodburning fireplace, A. chimney requirements – Hearth and Home Technologies EPA Certified Woodburning Fireplace 7100FP-GD-B User Manual

Page 21: Table 21.2, B. chimney termination requirements

Advertising
background image

September 1, 2008

433-1390G

Page 21

7100FP EPA Woodburning Fireplace

R

A. Chimney Requirements

Vertical distances are measured from the base of the fire-
place as shown in Figure 21.1.

To determine the chimney components needed to complete
your particular installation, follow the steps below:

• Determine the total vertical height of the fireplace

installation. This dimension is measured from the base of
the fireplace assembly to the point where the smoke exits
the termination cap.

Subtract the effective height of the fireplace assembly from
the overall height of the fireplace installation (measured
from the base of the fireplace to the bottom of the
termination cap, 13 ft. (4m).

• Refer to Table 21.2 to determine what components must

be selected to complete the fireplace installation.

• Determine the number of ceiling firestops, stabilizers,

roof flashing, etc. required to complete the fireplace
installation.

6 ft (1.8 m) max.
unsupported
run

20 ft (6.10 m) max.
pipe between an
offset & return

Ceiling firestop

35 ft (10.7 m)

max. straight

unsupported

chimney height

14.5 ft (4.42 m) min. height/single offset-return

20 ft. (6.10 m) min. height/double offset-return

50 ft (15.24 m) max. height

6 ft (1.83 m) max.
unsupported chimney
above roof

46 in.

(1168 mm)

to top of

standoffs

Figure 21.1 Chimney Requirements

Table 21.2

Fire Risk

Must maintain 2 in. (51 mm) air clearance
to insulation and other combustible
materials.

WARNING

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

Chimney Stabilizer

SL3

4-3/4

121

Ceiling Firestops

FS338

0

0

FS339

0

0

FS340

0

0

Offsets/Returns

SL315

13-3/8

340

SL330

15-1/2

394

Roof Flashing

RF370

0

0

RF371

0

0

Chimney Sections*

SL306

4-3/4

121

SL312

10-3/4

273

SL318

16-3/4

425

SL324

22-3/4 578

SL336

34-3/4 883

SL348

46-3/4 1187

* Dimensions reflect effective height.

Note: A maximum of two pairs of offsets and returns may
be used.

B. Chimney Termination Requirements

Minimum overall straight height

13 ft

3.96 m

Minimum height with single offset/
return

14.5 ft

4.42 m

Double offset/return minimum height

20 ft

6.1 m

Maximum height

50 ft

15.24 m

Maximum chimney length between an
offset and return

20 ft

6.1 m

Maximum distance between chimney
stabilizers

35 ft

10.67 m

Maximum unsupported chimney
length between the offset and return

6 ft

1.83 m

Maximum unsupported chimney
height above the fireplace

35 ft

10.67 m

Maximum unsupported chimney
above roof

6 ft

1.83 m

WARNING

• Do NOT connect this unit to a chimney flue

servicing another appliance.

• Do NOT connect to any air distribution duct or

system.

May allow flue gases to enter the house.

Asphyxiation Risk.