7100FP EPA Woodburning Fireplace

R

Figure 27.1 Ceiling/Attic Construction

Fire Risk

Must maintain 2 in. (51 mm) air clearance
to insulation and other combustible
materials.

WARNING

Mark the Exit Point of the Roof

Locate the point where the chimney will exit the roof by
plumbing down to the center of the chimney. Drive a nail
up through the roof to mark the center. See Figure 27.1.

• Cut Out the Hole in the Roof

Measure to either side of the nail and mark the 14-1/2 in.
x 14-1/2 in. (368 mm x 368 mm) opening required. This
is measured on the horizontal; actual length may be larg-
er depending on the pitch of the roof. Cut out and frame
the opening. See Chapter 25 of the Uniform Building
Code
for roof framing details.

• Assemble the Chimney Sections Through the

Roof

Continue to add chimney sections through the roof open-
ing, maintaining at least a 2 in. (51 mm) air space to com-
bustible materials.

• Install the Roof Flashing

If a roof flashing is to be used, install the roof flashing
appropriate to the roof pitch and install a termination cap
and storm collar following the instructions shipped with
the cap.

For chase installations you can use a round termination
cap, a round telescoping termination cap or a square
termination cap (See pages 61-62). A chase installation
must use a chase top. Chase tops are available from your
dealer. See page 14 for building a chase.

• Install the Chimney Air Kit (required in Canada):

When installing the chimney air kit, follow the instructions
provided with this accessory. See page 23.

• Completion of the Enclosure

Complete the fireplace enclosure, allowing space for
outside air ducts. Electrical wiring should not come in
contact with the fireplace. A minimum clearance of 1/2 in.
(13 mm) must be maintained between the fireplace
back and 1 in. (25 mm) minimum clearances to sides
and the enclosure.

NOTE: Wiring for blowers must be done before framed
enclosure is completed. If using a Heat Zone kit, it also
must be installed before enclosure is complete.