and Welcome to the Quadra-Fire Family

!

Hearth & Home Technologies welcomes you to our tradition
of excellence! In choosing a Quadra-Fire appliance, you
have our assurance of commitment to quality, durability, and
performance.

This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world’s most
advanced technology to achieve the optimum operation

of our stoves, inserts and fireplaces. And yet we are old-
fashioned when it comes to craftsmanship. Each unit is
meticulously fabricated and gold and nickel surfaces are
hand-finished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality
control inspection.

We wish you and your family many years of enjoyment in the
warmth and comfort of your hearth appliance. Thank you for
choosing Quadra-Fire.

SAMPLE: CLEARANCE TO COMBUSTIBLES LABEL

LOCATION: on hang tag on right side of fireplace

Manufactured
Date

Serial Number

Model Name

Test Lab
& Report No.

Model:

7100FP

E

PA

C

ERTIFIED

F

IREPLACE

Serial No / Numéro De Série

OMNI-Test Laboratories, Inc.

Report #061-S-41-2

LISTED FIREPLACE, SOLID FUEL TYPE, ALSO SUITABLE FOR MOBILE
HOME INSTALLATION. (UM) 84 HUD. "For Use with Solid Wood Fuel Only."

Install and use only in accordance with manufacturer's installation, venting and operating instructions.
Any area incorporating warm or cold air ducts shall be enclosed in accordance with the manufacturer's
installation instructions.
Contact Your Local Building Or Fire Officials Or Authority Having Jurisdiction About Restrictions,
Installation Inspection And Permits Required In Your Area.
WARNING - For Mobile Homes: Do not install in a sleeping room. An outside combustion air inlet
must be provided and unrestricted while unit is in use. The structural integrity of the mobile home floor,
ceiling and walls must be maintained. The fireplace needs to be properly grounded to the frame of the
mobile home.
Components required for installation: HTI SLSeries Pipe or Dura Plus System, Termination Cap, Hearth
Extension and required accessory Chimney Air Kit Part CAK4A.
Do not connect this unit to a chimney serving another appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing.
Electrical Rating: 115 VAC <3.0 AMPS 60 Hz
Do not use grate or elevate fire. Build wood fire directly on firebrick.
Do not overfire. If heater or chimney connector glows, you are overfiring.
Do not use a fireplace insert or other products not specified for use with this product.
WARNING - THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET OR ANY LOG SET.
TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET OR ANY LOG SET
INTO FIREPLACE.
Must provide a source of air to prevent air starvation from combustion which could result of high levels
of carbon monoxide.
Replace glass only with 5mm ceramic available from your dealer.
Optional Fire Screen Part Mesh-EPA, may be used ONLY in USA

Product covered by US Patents 4,766,876; 5,113,843; 5,341,794
Patent pending

Chimney sections at any level require a 2” (51mm) minimum
air space clearance between the framing and chimney section.

Minimum Clearances To Combustible Material

WITHIN ENCLOSURE AREA

Appliance to backwall

1/2" (13mm)

Appliance to sidewall

1" (25mm)

Duct boots to framing

0" (0mm)

Top standoffs to header

0" (0mm")


EXPOSED SURFACES

Faceplate to sidewall

16" (406mm)

Remote outlet air grills to ceiling 12" (305mm)

MANTEL

Mantel from base of fireplace

60" (1524mm)

Maximum mantel depth

12" (305mm)


FLOOR PROTECTION

U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to comply with July 1990 particulate emission standards.

2008 2009 2010 Jan Feb Mar Apr May June July Aug Sept Oct. Nov. Dec.

Made in U.S.A

DO NOT REMOVE THIS LABEL

433-1400

Mfg by:

Combustible flooring 20" (508mm) in front of and 8" (203mm) to
either side of the fuel opening must be insulated with
non-combustible floor protection with a minimum thickness of 1"
(25mm) and ("k" value = 0.43).

In Canada: The hearth extension must be installed according to
the installation instructions.

R

www.quadrafire.com

TESTED TO:

UL 127, ULC-S610-M87

SAMPLE

007

O-T L

Tested and

Listed by

Portland

Oregon USA

C

US

Page 2

433-1390G

September 1, 2008