7100FP EPA Woodburning Fireplace

Storm Collar

Flashing Collar

Top of Pipe

14-1/2 in. (368mm) max.

1-1/2 in. (38 mm) min.
overlap

2 in. (51 mm) min.

Figure 30.1 Installing a TR342 Round Telescoping Termination Cap

2 in. (51 mm) min.

4-1/2 in.

(114 mm)

max.

1-1/2 in.

(38 mm) min.

overlap

Cap Standoff

Top of Pipe

Flashing Collar

Figure 30.2 Installing an ST375 Square Termination Cap

Top of Pipe

2 in.

(51 mm)

min.

Flashing

Collar

1-1/2 in.

(38 mm)

min.

overlap

3 in.

(76 mm)

max.

Figure 30.3 Installing a TS345/TS345P Square Termination Cap

For installations utilizing an ST375 Square Termination

Cap the last chimney section must not be more than
4-1/2 in. (114 mm) below the chase top. See Figure
30.2.

For installations utilizing a TS345/TS345P Square

Termination Cap, the uppermost chimney section must
not be more than 3 in. (76 mm) below the chase top. See
Figure 30.3.

For chase installations you can use a Round Termination

Cap, a Round Telescoping Termination Cap, or a Square
Termination Cap.

Install termination caps following instructions provided

with them.

NOTE:

TR342/TR344: For less air restriction to flue

gases, use top vent kit listed in Section 12.

For installations utilizing a Round Telescoping Termination

Cap, the uppermost chimney section must be below the
top of the chase top, but not more than 14-1/2 in. (368 mm)
below the top of the chase top. Minimum overlap of
chimney and termination cap must be 1-1/2 in. (38 mm).
See Figure 30.1.