7100FP EPA Woodburning Fireplace

R

Figure 43.1 Mantel Specifications

60 in.

(1524mm)

Mantel

Clearances are
from bottom of
appliance to lower
edge of mantel or
trim

Trim

48 in.

(1219mm)

F. Mantel

A combustible mantel may be positioned no lower than 60

in. (1524mm) from the base of the fireplace.

The combustible mantel may have a maximum depth of 12

in. (305mm). Combustible trim pieces that project no more

than 3/4 in. (19mm) from the face of the fireplace can be

placed no closer than 6 in. (152mm) from the side of the

decorative front. See Figure 43.1.

Combustible trim must not cover:

• the metal surfaces of the fireplace

where the non-combustible board is placed over the metal
surfaces

• the space between the metal face of the fireplace and

framing members

Refer to page 12 for reduced mantel heights.