7100FP EPA Woodburning Fireplace

R

Figure 17.1 Outside Convection Air Placement

Outlet blocked by

snow, leaves, etc.

NO

Garage or

combustible

liquids storage

NO

Attic space

NO

Outlet placed

higher than 3 ft

below the

termination cap

NO

Use only duct materials
specified by manufacturer

Both the Outside Air and Auxiliary Air kits are installed

on the right hand side of the fireplace.

Left = Room Air Right =Auxiliary Air

B. Auxiliary Convection Air System

Figure 17.2 Auxiliary Convection Air Lever

Auxiliary convection air allows you to use outside air to flow
over the blowers, where it is heated and then distributed
into the room producing positive pressure inside the home.
Alternatively, you can also run a 6 in. (152 mm) duct to another
location in your home and use as a cold air return within the
home.

The auxiliary convection lever allows you to change the
fireplace from a zone heater into a whole house heater.

LEFT: Slide to the left and use the fireplace as a zone heater.
This option pulls room air into the bottom grille of the fireplace,
heats the air and re-circulates it to the room(s).

RIGHT: Slide to the right and use the fireplace as a whole
house heater for room convection air.

The auxiliary convection lever is located underneath the front
lower panel. See Figure 17.2.