7100FP EPA Woodburning Fireplace

Fascia

Outer Can
Flange

Ember Strip (Seal gap with
High temp, noncombustible
sealant able to withstand
300°)

Tile or
Marble

Minimum 2-1/4 in. (57mm) Cement Board

or equivalent, (or two 1/2 in. pieces)

and "k" value = 0.49. Micore 300

Minimum 20 in. (508mm) in front and

8 in. (203mm) on sides to fuel loading doors

Tile or
Marble

Combustible Floor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

Fascia

Outer
Can
Flange

Ember Strip (Seal gap
with high temp,
noncombustible sealant
able to withstand 300°)

Tile or Marble

Minimum 2-1/4 in.
57mm) Cement
Board or equivalent,
(or two 1/2 in. pieces)
and "k" value = 0.49.
Micore 300

Min 20 in. (508mm) in front and 8 in.
(203mm) on sides to fuel loading doors

Combustible
Floor

2 x 4

2 x 4

3/4 in.
(19mm)
Plywood

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Fascia

Outer
Can
Flange

Ember Strip
(Seal gap with
noncombustible
sealant)

Tile or Marble

Minimum 2-1/4 in. (57mm)
Cement Board or equivalent,
(or two 1/2 in. pieces) and
"k" value = 0.49. Micore 300

Min 20 in. (508mm) in front and 8 in.

(203mm) on sides to fuel loading doors

Combustible Floor

2 x 4

2 x 4

3/4 in.
(19mm)
Plywood

Non-combustible
framing materials

Figure 40.1 Fireplace and Hearth Extension Flush on the Floor.

Figure 40.2 Fireplace and Hearth Extension Flush on Floor but on Raised Platform

Figure 40.3 Raised Hearth Extension to Bottom of Fascia