Replacement parts, Caution – Hearth and Home Technologies EPA Certified Woodburning Fireplace 7100FP-GD-B User Manual

Page 31

Advertising
background image

September 1, 2008

433-1390G

Page 31

7100FP EPA Woodburning Fireplace

R

A. Blower Replacement

7

Replacement Parts

Screwdriver Slot

Screws

Unplug wire

harness before

removing fan

Blower Cord Location
The 7100FP Fireplace comes standard equipped with two
blowers, installed at the factory with electric access on the
right side of fireplace (as you face it).

Figure 31.1 Accessing Blower Motor

Figure 31.2 Blower Motor

Removing the Blower

1. Unplug the wire harness.

2. Lift blower from locating pins and remove. Repeat for

second blower if necessary. See Figure 31.2.

3. Connect new blower wires to wire harness.

4. Before installing the blower, make sure the grommets

are tightly in place. Insert the right blower and place
over the 2 locating pins. Repeat for other blower. Figure
31.3.

Blower Replacement Instructions

1. Remove the brick from the bottom of the fireplace and 3

of the back vertical bricks.

2. Remove the 2 screws from the access panel in the fire-

box floor. See Figure 31.1.

3. Pry up the access panel using the screwdriver slot and

completely remove the panel.

Figure 31.3 Installing Blowers

5. Re-install bottom panel or firebox access panel in

reverse order as described above.

6

Replace the brick that was removed.

7. Reconnect the power.

Shock Risk

Disconnect power by turning off circuit breaker
BEFORE servicing.

CAUTION