Listing and code approvals, Warning, Caution – Hearth and Home Technologies EPA Certified Woodburning Fireplace 7100FP-GD-B User Manual

Page 4

Advertising
background image

Page 4

433-1390G

September 1, 2008

R

7100FP EPA Woodburning Fireplace

1

Listing and Code Approvals

A. Appliance Certification

This appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is provided. The structural integrity of
the mobile home floor, ceiling, and walls must be maintained.
The fireplace must be properly grounded to the frame of the
mobile home and use only listed double-wall connector pipe.
Outside Air must be installed in a mobile home installation.

B. Mobile Home Approved

Model:

7100FP EPA Certified Woodburning
Fireplace

Laboratory:

OMNI Test Laboratories, Inc.

Report No:

061-S-41-2

Type:

Wood Fireplace

Standard:

UL127 and ULC-S610-M87 and

(UM) 84-HUD, Mobile Home

Approved.

An outside air termination cap is supplied with your 7100
Fireplace for installation in a mobile home. If you use
an alternative material it must be designed to prevent
material from dropping into the area beneath the mobile
home, and to prevent rodents from entering from the
outside.

This fireplace system has been tested and listed in
accordance with UL127 and ULC-S610-M87 standards,
and has been listed by OMNI Test Laboratories, Inc., for
installation and operation in the United States and Canada
as described in this manual. This fireplace has been tested
and listed for use with the SL-300 Series chimney (with
the the CAK4A Air Kit) and fireplace components listed in
Section 12. The Dura-Plus is also an approved venting
system manufactured by Dura-Vent Systems.

Check with your local building code agency before you begin
your installation to ensure compliance with local codes,
including the need for permits and follow-up inspections. Be
sure local building codes do not supersede UL specifications
and always obtain a building permit so that insurance protec-
tion benefits cannot be unexpectedly cancelled.

1. An outside air inlet must be provided for combustion and

must remain clear of leaves, debris, ice and/or snow. It
must be unrestricted while unit is in use to prevent room air
starvation which can cause smoke spillage and an inability
to maintain a fire. Smoke spillage can also set off smoke
alarms.

2. The fireplace is to be secured to the mobile home structure.

Use same holes that attached the fireplace to the pallet to
secure it to the floor using 1/4 in. x 2 in. (6 mm x 51 mm)
lag bolts or equivalent.

3. Unit must be grounded with #8 solid copper grounding

wire or equivalent and terminated at each end with N.E.C.
approved grounding device.

4. Refer to Minimum Clearances to Combustibles on pages

11-12 and chimney components on pages 62-63.

5. Floor protections requirements on pages 39-41 must be

followed precisely.

6. Use silicone to create an effective vapor barrier at the

location where the chimney or other component penetrates
to the exterior of the structure.

7. Follow the chimney and chimney connector manufacturer’s

instructions when installing the flue system for use in a mobile
home.

8. If unit burns poorly while an exhaust blower is on in home,

(i.e., range hood), increase combustion air.

NOTE: Top sections of chimney must be removable to

allow maximum clearance of 13.5 ft (411 cm) from ground
level for transportation purposes.

Fire Risk.

WARNING

For use with solid wood fuel only.
Other fuels may overfire and generate
poisonous gases (i.e. carbon monoxide).

CAUTION

Maintain structural integrity of mobile home:

• Floor, wall, ceiling and/or roof.

Do NOT cut through:
• Floor joist, wall, studs or ceiling trusses.
• Any supporting material that would affect the structural

integrity.

Never install in a sleeping room.

Consumes oxygen in the room.

WARNING

Asphyxiation Risk.