7100fp epa woodburning fireplace, C. diagnostics and problem solving – Hearth and Home Technologies EPA Certified Woodburning Fireplace 7100FP-GD-B User Manual

Page 55

Advertising
background image

September 1, 2008

433-1390G

Page 55

7100FP EPA Woodburning Fireplace

R

Diagnostic Question

Possible Causes of Condition

Solutions

Are the air controls open?

No draft

No combustion air

Open air controls

Is there enough paper?

Insufficient heat to ignite kindling

Use more paper

Is there enough kindling?
Is the kindling dry?

Insufficient heat to ignite fuel

Use drier kindling

Is there enough or too much wood?
Is it too large?
Is it dry enough?

Insufficient heat to establish draft

Insufficient air passage

Insufficient surface area

• Ignition temperature high due to

moisture

Use small split wood that is well sea-
soned (split, covered on top minimum 6
months, preferably a year)

Are there adequate air spaces
between fuel pieces?

Insufficient combustion air and exposed
surface area

Arrange kindling and wood for air move-
ment

Is the chimney pre-warmed?

Exposed, cold chimney downdrafting

Use lighted rolled newspaper at flue
opening to start upward air movement

Is there smoke in the house?

Obstruction in chimney

• Downdraft from chimney tempera-

ture or from negative house pres-
sure

• Have chimney checked if it worked

previously

• Pre-warm

chimney

Shut off exhaust devices

Open window slightly

Does the kindling wood not ignite?

Condition, amount, arrangement of
kindling and fuel

Use more, drier, well-spaced kindling
and fuel.

Does the kindling ignite, but the fuel
doesn’t?

Amount of kindling

Condition of fuel

Use more kindling

Use smaller, dry wood

Does the fuel ignite, but not burn well?

Draft problem

Condition of fuel

• Use well-seasoned wood and suf-

ficient amount

Turn exhaust fans off

Open window slightly

1. If I can’t get a good fire going, what am I doing wrong?

2. I smell smoke in the house after we have had a fire. What is the cause/what can I do?

Diagnostic Question

Possible Causes of Condition

Solutions

Is the chimney clean?

No: Creosote odor

Have chimney cleaned

3. I smell smoke in the house during operation. What is causing it?

Diagnostic Question

Possible Causes of Condition

Solutions

Do fires start and burn well?

No:
• Chimney

obstruction

• Not enough kindling and/or fuel to

establish draft

Inadequate combustion air

• Air controls not open

Yes:

Competition with exhaust devices

No:
• Check & clean chimney if needed

Use adequate kindling & fuel

Open air controls

• Open

window

• Check for need for balanced air

make-up (Outside Air)

• Check door rope for seal.
Yes:
• Do not use exhaust fans during

startup

• Check for need for balanced air

make-up (Outside Air)

C. Diagnostics and Problem Solving

Advertising