HP 2910AL User Manual
Page 194

Time Protocols
SNTP: Viewing, Selecting, and Configuring
==========================- CONSOLE - MANAGER MODE -========================
Switch Configuration - System Information
System Name : ProCurve
System Contact :
System Location :
Inactivity Timeout (min) [0] : 0 MAC Age Time (sec) [300] : 300
Inbound Telnet Enabled [Yes] : Yes Web Agent Enabled [Yes] : Yes
Time Sync Method [None] : TIMEP
TimeP Mode [Disabled] : Disabled
Server Address :
Tftp-enable [Yes] : Yes
Jumbo Max Frame Size [9216] : 9216
Time Zone [0] : 0
Jumbo IP MTU [9198] : 9198
Daylight Time Rule [None] : None
Time Protocol Selection Parameter
– TIMEP
– SNTP
Actions-> Cancel
Edit
Save
Help
– None
Figure 9-1. The System Information Screen (Default Values)
2. Press
[E] (for Edit). The cursor moves to the System Name field.
3. Use
[v] to move the cursor to the Time Sync Method field.
4. Use the Space bar to select
SNTP, then press
[v] once to display and move
to the
SNTP Mode field.
5. Do one of the following:
•
Use the Space bar to select the
Broadcast mode, then press
[v]
to
move the cursor to the
Poll Interval field, and go to step 6. (For
Broadcast mode details, refer to “SNTP Operating Modes” on
page 9-2.)
Time Sync Method [None] : SNTP
SNTP Mode [Disabled] : Broadcast
Poll Interval (sec) [720] :
720
Tftp-enable [Yes] : Yes
Time Zone [0] : 0
Daylight Time Rule [None] : None
Figure 9-2. Time Configuration Fields for SNTP with Broadcast Mode
•
Use the Space bar to select the
Unicast mode, then do the
following:
i.
Press
[>]
to move the cursor to the
Server Address field.
ii. Enter the IP address of the SNTP server you want the switch to
use for time synchronization.
9-6