HP 2910AL User Manual

Page 194

Advertising
background image

Time Protocols
SNTP: Viewing, Selecting, and Configuring

==========================- CONSOLE - MANAGER MODE -========================

Switch Configuration - System Information

System Name : ProCurve

System Contact :

System Location :

Inactivity Timeout (min) [0] : 0 MAC Age Time (sec) [300] : 300

Inbound Telnet Enabled [Yes] : Yes Web Agent Enabled [Yes] : Yes

Time Sync Method [None] : TIMEP

TimeP Mode [Disabled] : Disabled

Server Address :

Tftp-enable [Yes] : Yes

Jumbo Max Frame Size [9216] : 9216

Time Zone [0] : 0

Jumbo IP MTU [9198] : 9198

Daylight Time Rule [None] : None

Time Protocol Selection Parameter

– TIMEP
– SNTP

Actions-> Cancel

Edit

Save

Help

– None

Figure 9-1. The System Information Screen (Default Values)

2. Press

[E] (for Edit). The cursor moves to the System Name field.

3. Use

[v] to move the cursor to the Time Sync Method field.

4. Use the Space bar to select

SNTP, then press

[v] once to display and move

to the

SNTP Mode field.

5. Do one of the following:

Use the Space bar to select the

Broadcast mode, then press

[v]

to

move the cursor to the

Poll Interval field, and go to step 6. (For

Broadcast mode details, refer to “SNTP Operating Modes” on
page 9-2.)

Time Sync Method [None] : SNTP
SNTP Mode [Disabled] : Broadcast
Poll Interval (sec) [720] :

720

Tftp-enable [Yes] : Yes
Time Zone [0] : 0
Daylight Time Rule [None] : None

Figure 9-2. Time Configuration Fields for SNTP with Broadcast Mode

Use the Space bar to select the

Unicast mode, then do the

following:

i.

Press

[>]

to move the cursor to the

Server Address field.

ii. Enter the IP address of the SNTP server you want the switch to

use for time synchronization.

9-6

Advertising