N o t e – HP 2910AL User Manual

Page 350

Advertising
background image

Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch

N o t e

The

retries and timeout values are not used to send trap requests.

To verify the configuration of SNMPv2c informs, enter the

show snmp-server

command:

ProCurve(config)# show snmp-server

SNMP Communities

Community Name MIB View Write Access
---------------- -------- ------------
public Manager Unrestricted

Trap Receivers

Link-Change Traps Enabled on Ports [All] : All

...

Address

Community Events Sent Notify Type Retry Timeout

--------------------- --------------- ----------- ----------- ----- --------
15.28.333.456

guest

All

inform

SNMPv2c Inform
configuration

3

15

Excluded MIBs

Snmp Response Pdu Source-IP Information

Selection Policy : Default rfc1517

Trap Pdu Source-IP Information

Selection Policy : Configured IP

Ip Address : 10.10.10.10

Figure 14-9. Display of SNMPv2c Inform Configuration

14-22

Advertising