2-Way Voice Test Mode

At the Protected Premises:

To test the VIM and 6139AV keypad 2-way voice operation, both the installer at
the protected premises and the central station operator do the following.
NOTE: The VIM has built-in LEDs which identify its operating mode. It can be
helpful to view these LEDs when performing the following test. To view the
LEDs, remove the VIM's cover and refer to the table that follows.

VIM STATUS LED FUNCTIONS

LED

S T A T E

M E A N I N G

NO LED LIT

Off

VIM Idle

RED LIT

Steady

Talk to single keypad

Flashing

Talk to All Mode

GREEN LIT

Steady

VOX Mode

BOTH LIT

Steady

Listen to single keypad

Flashing in unison

Listen to All Mode

Alternating Flash

Waiting for operator's callback ID code

1. The installer enters the security code and presses #65 at a 6139AV 2-way

voice keypad.
The keypad displays "AUDIO 2WAY TEST" momentarily and a test message
is sent to the central station, with a "listen-in to follow" message (a Callback will
be required if in the Auto Callback mode).
The keypad then initially displays the "LISTEN MODE" message (if so
programmed via "VIM TEXT" option). Subsequently, this message changes,
depending on the 2-way voice mode the central station operator selects
(step 1 of "At the Central Station" below), such as "LISTEN MODE" (3
beeps), "TALK MODE" (1 beep), or "VOX MODE" (2 beeps).

2. The installer can say something verbally to the central station operator from

this keypad to confirm that the "listen-in" is working properly.

3. The installer should speak out loud near each of the 2-way voice keypads so

the operator can confirm their operation.

4. The installer can adjust the "Talk Mode" audio level using the procedure

described earlier.

At the Central Station:

1. When the test message and listen-in to follow message is received, the

operator lifts the receiver to begin a 2-way voice session and presses a
command key (see VIM OPERATOR FUNCTIONS section earlier in this
manual). If Auto Callback option is chosen, the operator will have to call back
within 5 minutes to begin a 2-way voice session.
The system defaults to "LISTEN MODE."

2. The operator should listen for the installer's verbal message. The operator

can then switch to "TALK MODE" or "VOX MODE" and say something to the
installer at the premises to confirm proper operation of these modes.

3. The operator should switch to each of the other installed 2-way voice

keypads and listen for the installer's verbal message.

4. The operator can switch to "talk Mode" and speak while the installer adjusts

the keypad's audio level.

5. In partitioned systems, repeat this test in each partition.

To test the operator-initiated callback feature and audio ID number, the
operator can enter Т88У, hang up, and call back within 5 minutes and enter
the proper ID code (field 1*59).

To end this test mode, the operator enters "99." This test mode also automatically
ends after 90 seconds if no commands are issued.