Guardian Technologies Ademco VISTA-40 User Manual

Page 26

Advertising
background image

Р 26 Р

Fault Annunciation

Since the phone module, RF receiver(s), VIM and the polling loop are shared

among the 2 partitions, the scheme for annunciating their failure follows:
Respective faults (for zones 87, 88Ð91, 93 & 97) will report as trouble conditions
only, and as such, should be assigned either zone type 00 if no annunciation is
desired, or zone type 05 if annunciation as trouble condition is desired. If the
polling loop or RF link fails, the corresponding zone number will display a trouble
condition for each partition that uses the device that failed. In addition, all zones
associated with that device will indicate a check condition. The trouble condition
will not interfere with the ability to arm the partition, but the faults must first be
bypassed.
N O T E :

5800 series transmitters have built-in tamper protection and will

annunciate a "CHECK" condition if cover is removed unless field *24 is disabled.

Important Battery Notice

The wireless transmitters are designed to provide long battery life under normal

operating conditions. Longevity of batteries may be as much as 4Ð7 years
depending on the environment, usage, and the specific wireless device being
used. External factors such as humidity, high or low temperatures, as well as large
swings in temperature may all reduce the actual battery life in a given installation.
The wireless system can identify a true low battery situation, thus allowing the
dealer or user of the system time to arrange a change of battery and maintain
protection for that given point within the system.
Button type transmitters should be periodically tested by the user for battery life
(ex. 5701, 5801, 5802, 5802MN, 5802CP, 5804).

Compatible 5700 Series

Wireless Devices

5701 Panic

Transmitter

Programmable for either silent or audible 24-hour alarm (can be DIP
switch programmed for zones 62 or 63).

5711

Slimline Door/Window Transmitter
Can be used with any closed circuit sensor. Can be used on any
zone 1Ð63 but, if set for zones 32-47, there will be a 3-minute lock-
out between transmissions.

5 7 1 1 W M Door/Window Transmitter w/Reed Switch

Can be used with any closed circuit sensor, on any zone 1Ð63 but, if
set for zones 32Ð47, there will be a 3-minute lock-out between
transmissions.

5 7 1 5 W H Universal Transmitter

DIP switch selectable for fast response, open or closed circuit sensor
usage, and has a tamper protected cover. Use in applications where
open circuit heat detectors are needed or where fast response
devices are needed. Can be used on any zone 1-63 but, if set for
zones 32Ð47, there will be a 3-minute lock-out between
transmissions.

5727 Wireless

Keypad

The keypad is identified as zone "00" when it transmits low battery
messages. The keypad panics are identified in the same way as wired
keypad panics (i.e. 95, 96 & 99).

5716 Door/Window

Transmitter

Can be used with any open or closed circuit sensor (DIP switch
selectable), and features a built-in reed switch. Can be used on any
zone 1-63 but, if set for zones 32-47, there will be a 3 minute lock-out
between transmissions.

5775 Wireless

PIR

DIP switch programmable for zones 32Ð47.
NOTE: There is a 3-minute lock-out between transmissions to
preserve battery life.

5706

Wireless Photoelectric Smoke Detector (System Sensor)
DIP switch programmable for zones 48Ð55.

5707

Wireless Photoelectric Smoke Detector (ESL)
DIP switch programmable for zones 48Р55.

Advertising